Installation Instructions for LP to Natural Gas Conversion

2 CHANGE BURNER ORIFICES (cont.)

IMPORTANT:

Orifices must be located exactly as shown.

Carefully read and observe each orifice label for correct
location.

MAIN

ORIFICES

C.

Install the proper orifices in the exact locations as noted

in the illustrations above.

D.

Return the LP gas orifices to the bracket and reattach

the bracket and the instruction sheet to the pressure

regulator using the screw removed previously.

E.

Replace the burner bases, heads, caps and top grates.

18

3 ADJUST BURNER FLAMES

A.

Turn all burners on highest setting and check the flames.

They should be blue (no yellow tipping) when using

natural gas. Foreign particles in the gas line may cause
an orange flame at first, but this will soon disappear.

B.

Turn the cooktop burner knob to "LO" while observing

the flame.

Adjust the setting of the upper row of flames using the
valve bypass screw as follows:

Adjustments must be made with two other burners in
operation on a medium setting. This prevents the upper

row of flames from being set too low, resulting in the flame
being extinguished when other burners are turned on.

C.

To adjust the flame, remove the knobs. Insert a screwdriver

through the access hole in valve shaft as shown.

E.

• If the flames were too small or fluttered, open the valve

more than the original setting.

• If the flames blew away from the burner, close the valve

more than the original setting.

D.

Make the adjustment by slowly turning the screw until

flame appearance is correct.

Testing Flame Stability:

Test 1

- Turn the knob from "HI" to "LO" quickly.

If the upper row of flames goes out at this setting,
increase the flame size and test again.

Test 2

- With the burner on "LO", open and close the

cabinet door under the cooktop. If the flame is
extinguished by the air currents created by the
door movement, increase the flame height and

test again.

NOTE:

When the burner is on the "SIM" setting, the upper

row of flames will go out.

Flame Recheck:

After the adjustment is made, turn all burners off. Ignite
each burner individually. Observe the flame at the "HI"

position. Rotate the knob to the lowest setting and be
sure that the flame size decreases as the knob is
rotated counterclockwise.

Once the conversion is complete and checked ok,

fill out the conversion sticker and include your name,

organization and date conversion was made. Apply

the sticker near the cooktop gas inlet opening to

alert others in the future that this appliance has been
converted. If converting back to the original gas, please
remove the sticker so others know the appliance is set to
use its original gas.

F.

Advertising