• Camera Configuration (CAM CON
FIG)
This item lets you set numbers for the input from system
cameras for RS-485 communication.
1. Move the cursor to CAM CONFIG by pressing the
A
or
T
button, then press the Q O'" 0 button. The CAMERA
CONFIG menu shown below will appear on the monitor
screen.
Baud Rate (BAUDRATE)
COMMUNICATION SETUP
UNIT
ADDRESS
rCAMlCONEIGl:’*
1
BAUD RATE
9600
DATA BIT
8
PARITY CHECK
NONE
STOP BIT
1
WAIT TIME
OFF
SETUP ENABLE
f
CAMERA CONFIG
INPUT CH
CAM NO.
A CH
:o:on
В CH
002
S-VIDEO
003
^
__
____ ^
2. Move the cursor to the input parameter to be edited by
pressing the
A
or
T
button, then select a number by
pressing the Q or 0 button.
Select a parameter value between 001 and 128.
The factory default setting for each input is shown
below.
A CH:
001
B CH:
002
S-VIDEO:
003
Note: Make sure not to assign the same number to
more than one system camera for RS-485 commu
nication.
3. Repeat the above procedure to edit other input.
4. After completing the settings, press the MENU button
to return to the previous setup menu.
This item lets you set the transmission speed for RS-485
communication,
1. Move the cursor to the BAUD RATE parameter by
pressing the
A
or ▼ button.
2. Select the desired transmission speed shown below by
pressing the Q or 0 button.
2 400
4 800 zr: 9 600 Г!: 19 200
The factory default setting is 9 600 bps.
• Data Bit (DATA BIT)
This item lets you set the number of data bits for RS-485
communication.
The factory default setting is 8 bit and fixed,
• Parity Check (PARITY CHECK)
This item lets you set the parity bit for RS-485 communica
tion.
1, Move the cursor to the PARITY CHECK parameter by
pressing the
A
or
T
button.
2. Select NONE, EVEN or ODD for parity check by press
ing the 0 or 0 button.
The factory default setting is NONE
• Stop Bit (STOP BiT)
This item lets you set the number of stop bits for RS-485
communication.
1. Move the cursor to the STOP BIT parameter by press
ing the
A
or ▼ button.
2. Select either 1 or 2 for number of stop bits by pressing
the
В
or
0
button.
The factory default setting is 1 bit.
• Wait Time (WAIT TIME)
This item lets you set the waiting time in milli-seconds (ms)
to retry after confirming that no data is received from the
controller for RS-485 communication.
1. Move the cursor to the WAIT TIME parameter by press
ing the
A
or
T
button.
2. Select OFF, 100, 200, 400, 1 000 ms for the wait time
by pressing the 0 or 0 button.