APPENDIX I: INPUT WIRING REQUIREMENTS

Input

Power Input

Current Input

Suggested Sizes (See Notes)

Voltage

Freq.

1-Ph

3-Ph

1-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

Wire (Canada)

(Volts)

(Hz)

(kVA)

(kVA)

(Amps)

(Amps)

1-Ph

3-Ph

1-Ph

3-Ph

1-Ph

3-Ph

208

50/60

18.9

17.3

91

48

100

60

2

4

2

4

230

50/60

18.9

17.3

82

43.5

90

50

2

6

2

6

240

50/60

19

17.5

79

42

80

50

2

6

2

6

380

50/60

21.2

19.1

55.9

29

70

35

4

8

4

8

415

50/60

21.2

19.4

51.2

27

60

35

6

8

6

8

460

50/60

21.2

20.4

46

25.6

50

30

6

8

6

8

575

Requires Transformer Module

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electrical Code

NOTES

The table above is based on the following output current & voltage: 140VDC @ 80A

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.

The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.

Cable conductor temperature used is 167° F (75° C).

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER

use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.

Flexible cable must have an outside diameter of 0.69 inches (17.5 mm) or greater.