07 primary input power cable connections, 07 primary input power cable connections -3, A. primary power cable connection procedure – Tweco 100XL Plus PAK Master Manuel d'utilisation

Page 21: Figure 3-2 voltage selection plug, Figure 3-3 voltage selection block installation, Figure 3-4 ac input power cable strain relief

Advertising
background image

Manual 0-2811

3-3

INSTALLATION

1. Pull the single wire voltage selection plug from the

connector mounted on the internal center chassis.

380-415V/460V

220V

460V

380-

415V

220V

380-

415V

460V

220V

380-415V/460V

220V

Voltage Selection

Plug (220V)

Voltage Selection

Plug (460V)

Voltage Selection

Plug (380-415V)

A-01361

Figure 3-2 Voltage Selection Plug

2. Loosen the screws securing the voltage selection block

to the terminal block.

3. Pull the voltage selection block up and out from the

terminal block.

4. Turn the voltage selection block to the desired volt-

age to be used. Use 220V for units using 208/230/
240V input and 380-415V/460V for 380/415V or 460V
input power.

5. Slide the voltage selection block onto the terminal

block and tighten all the screws.

NOTE

All screws must be tightened even if not used on
the terminal block.

380-415V/460V

220V

460V

380-

415V

220V

208/230/240VAC

380-

415V

460V

220V

380-415V/460V

220V

380-415V/460VAC

Voltage Selection

Block

A-01347

Figure 3-3 Voltage Selection Block Installation

6. Move the voltage selection plug to the desired input

connector for 220V (208/230/240V), 380/415V, or
460V input power operation.

3.07 Primary Input Power Cable

Connections

Units ordered as 230V, single-phase, will have a six foot
power input cable and plug factory installed. For all other
units, a cable must be provided by the end user. Recom-
mended cable sizes are specified in Appendix I.

A. Primary Power Cable Connection

Procedure

1. Route the primary power cable through the strain re-

lief fitting in the rear panel of the Power Supply and
tighten strain relief screws.

AC Input Power

Cable Strain Relief

AC Input

Power Cable

A-00912

Figure 3-4 AC Input Power Cable Strain Relief

2. Connect the input cable inside the Power Supply for

the type of operation as follows:

Three-Phase Operation

Three-phase operation requires a 3-conductor cable
with ground.

a. Locate the ground stud and remove the top

nut and washer.

b. Install a lug terminal on the ground wire.

c. Place the ground wire onto the ground stud

and secure with the nut and washer.

d. Insert the other three wires into the L1, L2, and

L3 terminals on the contactor.

e. Tighten all set screws.

f. Verify unused jumper wire is connected only

to the L3 terminals.

NOTE

The jumper wire from L1 to L4 must not be re-
moved.