Tweco 100XL Plus PAK Master Manuel d'utilisation

Page 29

Advertising
background image

Manual 0-2811

3-11

INSTALLATION

2. Using customer supplied CNC Cable

a. Remove the Left Side Panel from the Power

Supply as viewed from the front of the unit.

b. Remove the 7/8" knockout from the Rear

Panel and install a 1/2" NPT strain relief (not
supplied) into the hole.

CNC Knockout

A-02756

Rear Panel

1/2" (12.7 mm)

Strain Relief

(Customer Supplied)

Figure 3-13 Rear Panel Knockout Location

c. Locate the internal terminal block (TB) on the

Filter/Voltage Divider PC Board, located be-
hind the Logic PC Board. The terminal block
(TB) is plugged into a socket on the Filter/Volt-
age Divider PC Board.

A-02762

Logic PC Board

Internal Terminal

Block (TB)

Filter/Voltage Divider

PC Board

Figure 3-14 Internal Terminal Block Location

d. Feed the CNC cable through the strain relief

at the rear of the Power Supply, routing the
cable above the Logic PC Board to the Termi-
nal Block (TB).

A-02763

Internal Terminal

Block (TB)

CNC Cable Routing

Figure 3-15 Routing CNC Cable