Tweco 100XL Plus PAK Master Manuel d'utilisation

Page 23

Advertising
background image

Manual 0-2811

3-5

INSTALLATION

B. Checking Air Quality

To test the quality of air, place the RUN/SET/LATCH
switch to SET position, place a welding filter lens in front
of the torch and turn on the gas. Any oil or moisture in
the air will be visible on the lens. Do not initiate an arc!

CAUTION

Air supply must be free of oil, moisture, and other
contaminants. Excessive oil and moisture may
cause double-arcing, rapid tip wear, or even com-
plete torch failure. Contaminants may cause poor
cutting performance and rapid electrode wear.

C. Gas Connections

The gas supply is connected to the Two Stage Air Line
Filter Assembly installed on the rear of the unit. The con-
nection is the same for compressed air or high pressure
gas cylinders.

Connect the gas supply as follows:

1. Connect the gas line to the Regulator / Filter As-

sembly inlet port as shown. The illustration shows
typical fittings as an example. Other fittings may
be used. Install the fittings and tighten.

NOTE

Supply hose must be at least #4 hose (1/4 in or 6
mm I.D.).

Two Stage Filter

Assembly

1/4 NPT to

#4 (6mm) Hose

Fitting

#4 (6mm) Gas

Supply Hose

Hose Clamp

A-02744

Figure 3-8 Gas Connection To Two Stage Filter

Assembly

D. Optional Air Line Filter Installation

Filtering is required when using air from a compressor to
ensure that moisture and debris from the supply hose do
not enter the torch. Although the unit is standard with
the Two Stage Air Filter there is an Optional Single-Stage
Filter Assembly that may be used. Install the Optional
Single-Stage Filter as follows:

1. Remove the air hose connected between the Two

Stage Air Filter OUT port and the Regulator/Fil-
ter Assembly.

2. Connect the gas line to the Regulator / Filter As-

sembly inlet port as shown. The illustration shows
typical fittings as an example. Other fittings may
be used. Install the fittings and tighten.

NOTE

Supply hose must be at least #4 hose (1/4 in or 6
mm I.D.).

A-02753

1/4 NPT to
#4 (6mm)
Hose Fitting

Dry Air Filter
Assembly

#4 (6mm)
Gas Supply
Hose

Hose Clamp

Figure 3-9 Gas Connection to Optional Single-Stage

Filter Assembly

Advertising