10 ground connections for mechanized applications – Tweco 100XL Plus PAK Master Manuel d'utilisation

Page 26

Advertising
background image

INSTALLATION

3-8

Manual 0-2811

4. Connect the ATC Adapter or Torch Leads Nega-

tive / Plasma Lead to the bulkhead connection
inside the Power Supply.

5. Remove the top nut and washer from the Pilot

Stud.

6. Connect the pilot lead terminal to the stud and

secure with the nut and washer removed previ-
ously.

7. Connect the ATC Adapter or Torch Leads connec-

tors to the power supply adapter.

WARNING

The Shielded ATC Adapter includes two connec-
tors that are not used and must be taped out of the
way to prevent contacting the Negative / Plasma
or Pilot Leads.

8. Tighten the Strain Relief onto the or Torch Leads

ATC Adapter leads.

9. In applications using the torches with ATC Con-

nectors,

connect the torch leads male connector

to the ATC female receptacle. The connectors
should push together with a very small amount
of pressure. Secure the connection by turning the
locking nut clockwise until it stops. DO NOT use
the locking nut to pull the connection together.
Do not use tools to secure the connections.

A-03627

1

2

ATC Male
Connector

ATC Adapter
Female Receptacle

Torch Leads

To

Power Supply

Torch Connection - Torch Leads with ATC Male

Connector, Power Supply with ATC Adapter

10. Check the torch for proper consumable parts.

CAUTION

The torch parts must correspond with the type of
operation. Refer to the torch manual for details.

3.10 Ground Connections For

Mechanized Applications

A. Electromagnetic Interference (EMI)

Pilot arc initiation generates a certain amount of electro-
magnetic interference (EMI), commonly called RF noise.
This RF noise may interfere with other electronic equip-
ment such as CNC controllers, remote controls, height
controllers, etc. To minimize RF interference, follow these
grounding procedures when installing mechanized sys-
tems:

B. Grounding

1. The preferred grounding arrangement is a single point

or “Star” ground. The single point, usually on the
cutting table, is connected with 1/0 AWG (European
50 mm

2

) or larger wire to a good earth ground (refer

to paragraph ‘C’, Creating An Earth Ground). The
ground rod must be placed as close as possible to the
cutting table, ideally less than 10 ft (3.0 m), but no
more than 20 ft (6.1 m).

NOTE

All ground wires should be as short as possible.
Long wires will have increased resistance to RF
frequencies. Smaller diameter wire has increased
resistance to RF frequencies, so using a larger di-
ameter wire is better.

2. Grounding for components mounted on the cutting

table (CNC controllers, height controllers, plasma re-
mote controls, etc.) should follow the manufacturer’s
recommendations for wire size, type, and connection
point locations.

For Thermal Dynamics components it is recom-
mended to use a minimum of 10 AWG (European 6
mm

2

) wire or flat copper braid with cross section equal

to or greater than 10 AWG connected to the cutting
table frame. The connection point must be clean bare
metal; rust and paint make poor connections. For all
components, wires larger than the recommended
minimum can be used and may improve noise pro-
tection.

3. The cutting machine frame is then connected to the

“Star” point using 1/0 AWG (European 50 mm

2

) or

larger wire.