Manual No. 0-4816 Auto-Cut 200
2
4-6
OPERATION
Adjusts the output amperage of the power supply.
ENABLE
STATUS
DISABLE
PLASMA
POWER
SUPPLY
SHIELD
FLOW
GAS
PRESSURE
MODE
GAS
GCM
2000
PLASMA
PREFLOW
9
9
H20
MIST
RUN
SET PREFLOW
SET PLASMA
& SHIELD
TEST
Automated
Plasma Cutting System
AMPS
Thermal Dynamics
O
2
- AIR
H35 - N
2
AIR - AIR
N
2
- H
2
O
AMPS
Art # A-06892
5
6
4
3
7
8
The DISABLE position removes input power from the Power Supply inverters, disables the coolant pump and
fan, the pilot contactor & HF and removes AC power from the gsa control solenoids shutting off all gas flow.
When the switch is returned to the ENABLE position an automatic gas purge is started and then the system is
returned to normal operation under control of the CNC device.
Used to set preflow gas pressure. MODE switch must be in SET PREFLOW position.
Used to set plasma and shield gas pressures and flows. MODE switch must be in SET PLASMA & SHIELD
position.
Used to set water flow rate. MODE switch must be in SET PLASMA & SHIELD position. GAS selection switch
must be in N
2
-H
2
O position.
Water mist is not used in all applications. Ohmic height sensing is not recommended with water mist shield.
Water on the plate interferes electrically with the ohmic sensing system.
At lower flow rates the shield gas pressure is first set per the cut charts then the flow is set using the flow meter
with the Gas switch set in the “Flow” position. Some torch parts require higher flow rates that exceed the
capacity of the flow meter. In those cases, set the Gas switch to the Pressure position and use the regulator and
gauge to set the pressure per the cut charts.