Manual No. 0-4816 Auto-Cut 200

2

4-6

OPERATION

Adjusts the output amperage of the power supply.

ENABLE

STATUS

DISABLE

PLASMA
POWER
SUPPLY

SHIELD

FLOW

GAS

PRESSURE

MODE

GAS

GCM
2000

PLASMA

PREFLOW

9

9

H20

MIST

RUN

SET PREFLOW

SET PLASMA

& SHIELD

TEST

Automated

Plasma Cutting System

AMPS

Thermal Dynamics

O

2

- AIR

H35 - N

2

AIR - AIR

N

2

- H

2

O

AMPS

Art # A-06892

5

6

4

3

7

8

The DISABLE position removes input power from the Power Supply inverters, disables the coolant pump and
fan, the pilot contactor & HF and removes AC power from the gsa control solenoids shutting off all gas flow.
When the switch is returned to the ENABLE position an automatic gas purge is started and then the system is
returned to normal operation under control of the CNC device.

Used to set preflow gas pressure. MODE switch must be in SET PREFLOW position.

Used to set plasma and shield gas pressures and flows. MODE switch must be in SET PLASMA & SHIELD
position.

Used to set water flow rate. MODE switch must be in SET PLASMA & SHIELD position. GAS selection switch
must be in N

2

-H

2

O position.

Water mist is not used in all applications. Ohmic height sensing is not recommended with water mist shield.
Water on the plate interferes electrically with the ohmic sensing system.

At lower flow rates the shield gas pressure is first set per the cut charts then the flow is set using the flow meter
with the Gas switch set in the “Flow” position. Some torch parts require higher flow rates that exceed the
capacity of the flow meter. In those cases, set the Gas switch to the Pressure position and use the regulator and
gauge to set the pressure per the cut charts.