Section 3: installation, 01 installation requirements, Section 3: installation -1 – Tweco 20 O2 Auto-Cut Manuel d'utilisation

Page 25: 01 installation requirements -1

Advertising
background image

Manual No. 0-4816 Auto-Cut 200

2

3-1

INSTALLATION

SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This
conformity shall be checked by qualified personnel.

Input

Power Input

Current

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

208

60

47

130

160

#2

2

230

60

49

125

150

#2

2

400

50

54

77

100

#2

1

400 (CE)

50

54

77

100

#2

1

460

60

59

75

90

#2

1

Auto-Cut 20O

2

Power Supply Electrical Inputs

2

Extra Hard Usage Type G, G-GC, W

Suggested Sizes (See Note)

Line Voltages with Suggested Circuit Protection and Wire Sizes

1

Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW

Based on National Electric Code and Canadian Electrical Code

Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type of
wire being used and method of installation.

Gas Supply

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure
regulators must be double-stage and installed as close as possible to the gas console. Contaminated gas
can cause one or more of the following problems:

Reduced cutting speed

Poor cut quality

Poor cutting precision

Reduced consumables life.

Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.

Gas supply leads must be #8 (1/2 in. ) hose or larger

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Thermal Dynamics recommends its coolants 7-3580 and 7-3581 (for low temperatures).

Cat. Number and Mixture

Mixture

Protects To

7-3580 'Extra-Cool

TM

'

25 / 75

10° F / -12° C

7-3581 'Ultra-Cool

TM

'

50 / 50

-27° F / -3° C

7-3582 'Extreme Cool

T M

'

Concentrate*

-65° F / -51° C

Coolant Capabilities

* For mixing with D-I Cool

TM

7-3583

Advertising