background image

Manual No. 0-4816 Auto-Cut 200

2

4-1

OPERATION

SECTION 4: OPERATION

4.01 Power Supply Control Panel

Art # A-04862

AC Indicator

Temp Indicator

Gas Indicator

DC Indicator

Status Indicator

Indicates AC power is being supplied to the inverters when the ON/OFF switch is in ON position. When
switch is first set to ON, the indicator stays off until the inrush cycle is complete and the correct voltage is
confirmed.

Normally OFF. Indicator turns ON when the internal temperature sensors detect tempera-

tures above normal limits. Let the unit cool before continuing operation.

The indicator blinks when the gas control is not ready. Causes for not being ready are when

purging, Mode switch is not set to Run, gas pressure is not correct or there are communiation errors. When gas
flow is called for (preflow, cutting, postflow ) the indicator is on steady. It is off at all other times.

Indicates the power supply is generating output DC voltage.

Shows system status. The number of flashes indicates the status. Refer to the Status

Code Section for details. On power supply start-up, the indicator flashes to show the revision level of the
operating software installed in the system.