North american hazardous location approval – Rockwell Automation 1762-IQ32T MicroLogix DC Input Module Manuel d'utilisation

Page 4

Advertising
background image

4 MicroLogix 1762-IQ32T DC Input Module

Publication 1762-IN019B-EN-P - June 2013

North American Hazardous Location Approval

The following modules are North American Hazardous Location approved: 1762-IQ32T

The following information applies when
operating this equipment in hazardous
locations:

Informations sur l’utilisation de cet
équipement en environnements dangereux:

Products marked "CL I, DIV 2, GP A, B, C, D" are
suitable for use in Class I Division 2 Groups A, B, C,
D, Hazardous Locations and nonhazardous
locations only. Each product is supplied with
markings on the rating nameplate indicating the
hazardous location temperature code. When
combining products within a system, the most
adverse temperature code (lowest "T" number) may
be used to help determine the overall temperature
code of the system. Combinations of equipment in
your system are subject to investigation by the
local Authority Having Jurisdiction at the time of
installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne
conviennent qu'à une utilisation en environnements de
Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des
marquages sur sa plaque d'identification qui indiquent
le code de température pour les environnements
dangereux. Lorsque plusieurs produits sont combinés
dans un système, le code de température le plus
défavorable (code de température le plus faible) peut
être utilisé pour déterminer le code de température
global du système. Les combinaisons d'équipements
dans le système sont sujettes à inspection par les
autorités locales qualifiées au moment de l'installation.

WARNING

EXPLOSION HAZARD

• Do not disconnect equipment

unless power has been removed or
the area is known to be
nonhazardous.

• Do not disconnect connections to

this equipment unless power has
been removed or the area is known
to be nonhazardous. Secure any
external connections that mate to
this equipment by using screws,
sliding latches, threaded
connectors, or other means
provided with this product.

• Substitution of components may

impair suitability for Class I,
Division 2.

• If this product contains batteries,

they must only be changed in an
area known to be nonhazardous.

• All wiring must comply with N.E.C.

article 501-4(b).

• The interior of the enclosure must

be accessible only by the use of a
tool.

• For applicable equipment (relay

modules, etc.), exposure to some
chemicals may degrade the sealing
properties of materials used in the
following devices: Relays, Epoxy. It
is recommended that the User
periodically inspect these devices
for any degradation of properties
and replace the module if
degradation is found.

AVERTISSEMENT

RISQUE D’EXPLOSION

• Couper le courant ou s’assurer que

l’environnement est classé non
dangereux avant de débrancher
l'équipement.

• Couper le courant ou s'assurer que

l'environnement est classé non
dangereux avant de débrancher les
connecteurs. Fixer tous les connecteurs
externes reliés à cet équipement à
l'aide de vis, loquets coulissants,
connecteurs filetés ou autres moyens
fournis avec ce produit.

• La substitution de composants peut

rendre cet équipement inadapté à une
utilisation en environnement de Classe
I, Division 2.

• S’assurer que l’environnement est

classé non dangereux avant de changer
les piles.

Advertising