Installation – Garland GD SERIES GAS COUNTER UNITS Manuel d'utilisation

Page 5

Advertising
background image

Part # 4519762 (12/07)

Page 5

INSTALLATION

General

1. Carefully remove unit from carton or crate. Burner tie

wires and other packing material should be removed
from units. On stainless steel units, the protective
material covering the stainless steel should be removed
immediately after the unit is installed.

2. Remove top grates and place in a safe area to prevent

damage.

3. Should it be necessary to remove the steel griddle plate

on units equipped with griddle thermostats, the griddle
thermostat bulb and capillary must first be withdrawn
from the bulb shield assembly, located on the underside
of the griddle plate. This can be accomplished with the
griddle front raised and supported by the griddle prop
located on the underside of the griddle plate. Loosen the
four pal nuts securing the bulb shield assembly to the
griddle plate and withdraw the griddle thermostat bulb.

4. When a griddle plate is being installed on units equipped

with griddle thermostats, the thermostat bulb must
be inserted in the groove between the plate and the
bulb shield assembly. This can be accomplished with
the griddle front raised and supported by the griddle
prop, located on the underside of the griddle plate. It is
important for accurate temperature control that the bulb
be located inside the groove. Tighten the four pal nuts
securing the bulb shield assembly to the griddle plate.

5. These units must be installed under an adequate

ventilation system. Refer to section titled Ventilation for
further instructions.

6. All burner adjustments and setting shall be made by a

qualified gas technician.

Clearances

MINIMUM INSTALLATION CLEARANCES TO

ADJACENT COMBUSTIBLE/NON-COMBUSTABLE

WALLS OR BASE

Model #

Sides & Back

Floor Or

Base

C

ombustible

Non

C

ombustible

GD-152H(J)(FF),
GD-302H(J)(FF),
GD-304H(J)(FF)

6”

(152mm)

0”

Combustible

GD-15F(J)

6”

(152mm)

0”

Non

Combustible

GD-15G(J)(FF),
GD-25G(J)(FF),
GD-36G(J)(FF),
GD-15GTH(J),
GD-24GTH(J),
GD-36GTH(J)

6”

(152mm)

0”

Combustible

FOR INSTALLATION IN

NON COMBUSTIBLE LOCATIONS ONLY

GD-18RB(J)(FF),
GD-24RB(J)(FF),
GD-30RB(J)(FF),
GD-36RB(J)(FF)

N/A

0”

Non

Combustible

Advertising