Problem

Cause

Solution

1. Power light not Illuminated

No AC power

Check GFI and incoming power

Controller failure

Contact Dealer or Installer

2. Ionizing Indicator Display reads “00”

Probe exhausted

Inspect and replace Probe if exhausted
Check to make sure all of the Probe

cable connectors are properly

installed and the cables have not been

accidentally damaged or cut

3. I onization level not able to be raised

to full power

Insufficient water flow through Flow

Chamber

Scale build-up or debris suffocating

Probe

Water chemistry make-up

Move Probe to area of greater water

flow. Plumbing into the water feature’s

recirculating system is the most effective

method.
An excessive build-up of scale on the

bars is an indicator that there may not

be sufficient water flow. The scale will

decrease the distribution of ions being

released into the water, as well as

affect the ability to raise and lower the

Control Panel’s ionization level. The

scale can be easily brushed or scraped

off the bars which will improve the

Probe’s performance immediately. If you

notice the scale repeatedly building up

then you may want to move the Probe

to a location with higher water flow,

such as plumbed directly into the main

recirculating system.
Water chemistry also plays a role in the

ability of the ionization level to be raised

or lowered, as well as the effectiveness

of the copper ions in the water. See

Targeted Water Parameters section

below the troubleshooting table.

4. Continued scale build-up on

Probe bars

Insufficient water flow across Probe

See #3 solutions

• The Flow Chamber, when plumbed directly into the

recirculating system, needs to be located in a region that will

drain for servicing the replaceable IonGen

Probe, as well

as allowing the Flow Chamber fitting to over-winter.

• If shutting down the water feature during the winter, make

sure the plumbing line is drained free of water. Failure to

do so may cause water remaining in the plumbing line to

freeze, potentially cracking the Flow Chamber and voiding

the warranty.

• Prior to restarting the IonGen

in the spring, it is a good

idea to remove and inspect the Probe to ensure it is

free of debris and scale build-up, and not exhausted or

worn. Scrape away any scale build-up from the Probe’s

bars. Replace worn Probes. See section above on Probe

Maintenance for more information.

troubleshooting guide

ImPOrtant: Before installing the IonGen

System on an existing water feature, it is recommended to thoroughly clean

the pond of as much debris as possible. This will maximize the ion’s effectiveness and speed to achieve desired results.

The more debris present in the water feature, the longer it will take for the IonGen

to provide noticeable results.