Aquascape IonGen Generation G2 (95012) Manuel d'utilisation
Page 4
4
☎
US 1-866-877-6637 |
☎
CAN 1-866-766-3426 | www.aquascapeinc.com
video on IonGen
™
safety information
• Read the Installation Instruction and Maintenance
Owner’s Manual before installing.
• Follow all local codes for installation.
• To reduce the risk of electric shock, connect only to a
properly grounded, ground fault interrupter (GFI).
• Do not immerse the IonGen™ Control Panel in water.
• It is a violation of Federal Law to use this product in a
manner inconsistent with its labeling.
iongen
™
sPecifications
• Input Voltage: 120 Volts
• Input Frequency: 60 Hz
• Output Voltage: 12 V
• Output Current: 0.5A
• Plug-in Transformer: UL Listed, CSA Listed
Rainproof Class 2
• Flow Chamber: Injection Molded Plastic
• Probe Material: 99% Copper
• Capacity: Up to 25,000 gallon water features
installation for the aquascaPe
iongen
™
system
ImPOrtant: Before installing the IonGen
™
System in existing water features it is
recommended to thoroughly clean the pond of
as much debris as possible. This will maximize the ions’
effectiveness and speed to achieve desired results. The more
debris and dirtier the water feature, the longer it will take the
Aquascape IonGen
™
System to provide noticeable results.
1. Mount the IonGen
™
Control Panel
Mount the IonGen
™
Control Panel in the
desired location; making
sure the power cord
reaches the GFI outlet
and the Probe cord
reaches the desired
location of the Probe.
A 25’ extension Cable
with Quick Connects (sold separately) is available, if needed.
The IonGen
™
Control Panel is weather-resistant, but in order
to maximize the lifespan of your unit, we suggest mounting the
panel above ground in a location protected from the elements.
2. Install the Flow Chamber
The Flow Chamber for the IonGen
™
can be located in
several areas within the water feature. The Flow Chamber is
most effective when plumbed directly into the water feature’s
recirculating system. The Probe can also be installed without the
Flow Chamber by submerging it in a filter, such as in a skimmer
or Pondless
®
Waterfall filter. Follow the step-by-step installation
instructions for the method you select.
INSTALLATION OPTION A:
Flow Chamber Installed into Recirculating System
• Cut and insert the Flow
Chamber into the water
feature’s recirculating system.
The Flow Chamber should
be positioned after the
water feature’s pump, and
in a region of the plumbing
line that drains by gravity.
This is enables you to easily
service the Probe and allows
for overwintering the Flow
Chamber and fittings. It
is recommended to use a
pre-filter, such as a skimmer,
prior to the Flow Chamber,
in order to remove solids
and debris that may interfere
with the Probe. A small valve
box may be used for easy
access during maintenance.
• Select the fittings needed for the application. The PVC slip
fitting is designed to be used with Schd 40 PVC pipe (Rigid
or Flex) and PVC glue. The multi-hose adapter fitting is
designed to be used with kink-free pipe and hose clamps.
2” PVC Slip Fitting
Multi-Hose
Adapter