JLG 660SJ Operator Manual Manuel d'utilisation
Page 123

SECTION 6 - CARACTÉRISTIQUES GÉNÉRALES ET MAINTENANCE POUR L'OPÉRATEUR
3122533
– Élévateur JLG –
6-19
(HYD. OIL TANK TEMP.)
IF EITHER OR BOTH CONDITIONS
EXIST JLG HIGHLY RECOMMENDS
THE ADDITION OF A HYDRAULIC
OIL COOLER (CONSULT JLG SERVICE
180° F (82° C)
PROLONGED OPERATION IN
AMBIENT AIR TEMPERATURES
OF 100° F (38° C) OR ABOVE.
EXTENDED DRIVING WITH
HYDRAULIC OIL TANK
TEMPERATURES OF 180° F
(82°C) OR ABOVE.
NO OPERATION BELOW THIS
AMBIENT TEMPERATURE
M
O
B
IL
4
2
4
1
0
W
-3
0
HYDRAULIC
SPECIFICATIONS
NO OPERATION ABOVE THIS
AMBIENT TEMPERATURE
DO NOT START UP HYDRAULIC SYSTEM
WITHOUT HEATING AIDS WITH MOBILE 424
HYDRAULIC OIL BELOW THIS TEMPERATURE
DO NOT START UP HYDRAULIC SYSTEM
WITHOUT HEATING AIDS AND COLD WEATHER
HYDRAULIC OIL BELOW THIS TEMPERATURE
E
X
X
O
N
U
N
IV
IS
H
V
I
2
6
M
O
B
IL
D
T
E
1
3
NOTE:
1) RECOMMENDATIONS ARE FOR AMBIENT TEMPERATURES
CONSISTENTLY WITHIN SHOWN LIMITS
2) ALL VALUES ARE ASSUMED TO BE AT SEA LEVEL.
-40° F (-40° C)
-30° F (-34° C)
-20° F (-29° C)
-10° F (-23° C)
0° F (-18° C)
10° F (-12° C)
20° F (-7° C)
30° F (-1° C)
40° F (4° C)
50° F (10° C)
60° F (16° C)
70° F (21° C)
80° F (27° C)
90° F (32° C)
100° F (38° C)
110° F (43° C)
120° F (49° C)
AMBIENT AIR
TEMPERATURE
SPÉCIFICATIONS
HYDRAULIQUES
CONDUITE PROLONGÉE AVEC DES TEMPÉRATURES DE
RÉSERVOIR D'HUILE HYDRAULIQUE DE 82 °C (180 °F) OU PLUS.
SI UNE DE CES SITUATIONS OU LES DEUX SONT PRÉSENTES, JLG RECOMMANDE
FORTEMENT L'AJOUT D'UN REFROIDISSEUR D'HUILE HYDRAULIQUE
(CONSULTER LE SERVICE APRÈS-VENTE DE JLG À CE PROPOS)
FONCTIONNEMENT PROLONGÉ À DES
TEMPÉRATURES D'AIR AMBIANT DE
38 °C (100 °F) OU PLUS.
UTILISATION INTERDITE
AU-DESSUS DE CETTE
TEMPÉRATURE AMBIANTE
82 °C (180 °F)
(TEMP. DU RÉS. D'HUILE
HYD.)
TEMPÉRATURE
AMBIANTE
UTILISATION INTERDITE AU-DESSOUS DE
CETTE TEMPÉRATURE AMBIANTE
NOTE :
1. CES RECOMMANDATIONS SONT POUR
DES TEMPÉRATURES AMBIANTES
CONSTAMMENT DANS LES LIMITES
INDIQUÉES
2. TOUTES LES VALEURS SUPPOSENT QUE
LA MACHINE EST AU NIVEAU DE LA MER.
NE PAS DÉMARRER LE CIRCUIT HYDRAULIQUE SANS DISPOSITIFS D'AIDE AU CHAUFFAGE
AVEC L'HUILE HYDRAULIQUE MOBILE DTE 13 EN DESSOUS DE CETTE TEMPÉRATURE
Figure 6-6. Spécifications de température de fonctionnement du moteur - Caterpillar - Fiche 2 de 2
4150548-E
NE PAS DÉMARRER LE CIRCUIT HYDRAULIQUE SANS DISPOSITIFS
D'AIDE AU CHAUFFAGE AVEC L'HUILE HYDRAULIQUE MOBILE 424 EN
DESSOUS DE CETTE TEMPÉRATURE