Page 16: Fuel filter

Advertising
background image

PHOTOCELL

CLEAN PHOTOCELL ANNUALLY OR AS NEEDED.
- Remove upper shell (See page 14).
- Remove photocell from photocell bracket and disconnect

photocell from connector.

- Clean photocell lens with cotton swab.
- Inspect photocell for damage. If damaged, replace photocell.

FUEL LINES

TIGHTEN FUEL LINES ANNUALLY OR
AS NEEDED.
- Remove upper shell (See page 14).
- Use 1/4” wrench and tighten fuel line (A) at solenoid valve and at

pump (See Figure 19).

- Remove fan guard (See Figure 20,21).
- Use 3/8” wrench and tighten fuel line (B) at pump and pump fuel

filter assembly.

- Reinstall fan guard.

FUEL FILTER

CLEAN TWICE PER HEATING SEASON OR AS NEEDED.

4

16

MAINTENANCE (cont.)

Figure 18 – Clean Photocell Lens

Photocell Bracket

Photocell

Connector

Photocell Lens

Install Photocell
1) Incorrect

2) Correct

Figure 19 – Tighten Fuel Line

Burner Head

Solenoid

Valve

Fuel Line (A)

Fuel Line (B)

Figure 20 – Remove Fan Guard (CP400CK)

Fan Guard

Flat Washer

Screw

Figure 21 – Remove Fan Guard (CP650CK)

Fan Guard

Tank Fuel Filter
- Remove fan guard (See Figure 20,21).
- Disconnect fuel line (B) from pumpand pump fuel filter

assembly with 3/8” wrench (See Figure 19).

- Remove two screws that fix bracket-filter to shell lower and

remove bracket-filter.

- Carefully pry fuel filter loose from fuel tank with flat end of

screwdriver.

- Wash fuel lines and fuel filter with clean kerosene.
- Replace fuel filter into fuel tank.
- Replace bracket-filter to shell lower.
- Connect fuel lines (B) to pump and pump fuel filter assembly.
- Reinstall fan guard.