Operation (cont.) – L.B. White 400-650K Tradesman Manuel d'utilisation

Page 13

Advertising
background image

EXTRA ELECTRIC OUTLET

(For CP400CK only)
• Always cover electrical outlet when not in use. See Figure 11.
• Don't plug and use an appliance with more than 5A current in this

outlet.

LONG-TERM STORAGE OF YOUR HEATER

FUEL TANK DRAIN
1. Remove drain bolt from bottom of fuel tank . See

Figure 12.

2. Using a small amount of kerosene, swirl and rinse the

inside of the tank.

NEVER MIX WATER WITH KEROSENE, as it will cause rust inside

the tank. Pour the kerosene out, making sure that you remove it

all.

IMPORTANT:

Do not store kerosene over summer for use during next heating

season. Using old fuel may damage heater.

Tighten drain bolt firmly into the tank, otherwise it will not

seal completely.

- Make sure storage place is free of dust and corrosive fumes.

- Store the heater in the original box with the original packing

material and keep USER”S MANUAL with heater..

WARNING!

Shock hazard

-

Always cover outlet when not in use.

Figure 11 – Extra Electric Outlet

Cover

Electric Outlet

OPERATION (cont.)

4

13

Figure 12 – Drain Plug Removal

Fuel Drain Bolt

Seal