EXTRA ELECTRIC OUTLET
(For CP400CK only)
• Always cover electrical outlet when not in use. See Figure 11.
• Don't plug and use an appliance with more than 5A current in this
outlet.
LONG-TERM STORAGE OF YOUR HEATER
FUEL TANK DRAIN
1. Remove drain bolt from bottom of fuel tank . See
Figure 12.
2. Using a small amount of kerosene, swirl and rinse the
inside of the tank.
NEVER MIX WATER WITH KEROSENE, as it will cause rust inside
the tank. Pour the kerosene out, making sure that you remove it
all.
IMPORTANT:
Do not store kerosene over summer for use during next heating
season. Using old fuel may damage heater.
Tighten drain bolt firmly into the tank, otherwise it will not
seal completely.
- Make sure storage place is free of dust and corrosive fumes.
- Store the heater in the original box with the original packing
material and keep USER”S MANUAL with heater..
WARNING!
Shock hazard
-
Always cover outlet when not in use.
Figure 11 – Extra Electric Outlet
Cover
Electric Outlet
OPERATION (cont.)
4
13
Figure 12 – Drain Plug Removal
Fuel Drain Bolt
Seal