A.O. Smith 315795-000 MH Manuel d'utilisation

Page 10

Advertising
background image

10

FIGURE 7.

FIGURE 8.

FIGURE 9.

3. Insert the duct assembly as shown in Figure 10 with lip facing

forward, and using only nails, secure the duct assembly to the
fl oor.

FIGURE 10.

4. Set the water heater in place against the lip of the duct assembly

as shown in Figure 11.

FIGURE 11.

5. Secure the water heater to the duct assembly using the screw

provided.

NOTE: See pages 12 and 13 for installing an air intake through
an outside wall when the manufactured home is located over a
basement or crawl space
.

SECURING WATER HEATER TO FLOOR AND WALL

The water heater must be secured to the fl oor and to the wall of the
enclosure with the three mounting brackets and screws packaged in
the carton with the water heater. The two small brackets are used to
attach the water heater to the fl oor and the one large bracket is used
to secure the top of the water heater to the wall.

Because of installation variances these brackets can be located at
any points around the circumference of the jacket. When the bracket
locations are determined using the 1/8 inch drill bit for a pattern, drill
only through the outer jacket of the water heater. Then using the
screws provided, secure the bracket to the water heater, fl oor and
wall, see Figure 12.

FIGURE 12.

Advertising