4. Install a 3/4 in. union (optional) and

continue with pipe and 3/4 in. x 3/4 in. x 3/4

in. tee. (

Fig. 4)

368

Glue

Tee

Union

4

5. Make the connection to the house plumbing.

From the tee, install pipe and shut off valve

(optional). (

Fig 5)

L1386

6

6. Completed installation with piping and tank is

shown (

Fig. 6)

Glue

To House

Plumbing

From Pump

Shut off valve

5

TANK TO HOUSE CONNECTION (CONTINUED)

PUMP ELECTRICAL CONNECTIONS

IL1401

2

L1

L2

A

B

L1

L2

A

B

115 Volts

Single Phase

Line

230 Volts

Single Phase

Line

Y
E

L
L

O

W

W

H

I

T
E

G

R
E
Y

R
E

D

T

A
N

Y
E

L
L

O

W

W

H

I

T
E

G

R
E
Y

R
E

D

T

A
N

Check Voltage of Power Source

Before Connecting

DO NOT CONNECT ANY GROUND WIRE

TO THESE LEADS

WIRING DIAGRAM

2. Screw the pressure switch into the 1/4 in.

opening on the side of the flow control and

remove the switch cover. (

Fig. 2)

CAUTION: All wiring should be performed by a

qualified electrician in accordance with the National

Electric Code and local electric codes.

CAUTION: Connect the pump to a separate

electrical circuit with a dedicated circuit breaker. Refer to

the Wire Size Chart for proper fuse size.

WARNING: Under-size wiring can cause motor

failure and even fire. Use proper wire size specified in

the Wire size chart.

WARNING: Replace damaged or worn wiring cord

immediately.

WARNING: Do not kink power cable and never

allow the cable to come in contact with oil, grease, hot

surfaces, or chemicals.

CAUTION: Protect the power cable from coming in

contact with sharp objects.

WARNING: The pump must be properly grounded

using the proper wire cable with ground.

WARNING: Always disconnect pump from

electricity before performing any work on the motor.

Motor:

98L105

HP:

1/2

PH

1

Hz

60

Volts

115/230

S.F.

1.2

Amps

6.4/3.2

S.F. Amps:

8.6/4.3

RPM

3450

Type

C

Duty:

Cont.

Temp

65C

KVA Code

G

Frame

56L

Ins Class

B

Factory prewired for 115V

Thermally protected automatic

Check voltage of power source

Use copper conductors only

ELECTRICAL HAZARD

Improper installation may result in fi re, explosion, electrical short or injury. Replace all covers

before operating. Ground motor in accordance with local and national electrical codes.

Disconnect power source before touching internal parts. Motors equipped with automatic

protection may restart without warning.

See instruction manual for proper installation procedure.

Se reporter au manuel d’instructions pour suivre la procédure adéquate d’installation.

Consulte el instructive para conocer el procedimiento de instalación correcto

1

Wiring The Pressure Switch

1.

CAUTION: Make certain that the power

source matches the pump requirements. This

pump has a dual voltage motor and can run

on 115V or 230V. See motor nameplate for

voltage prewired at the factory.

(Fig. 1)

NOTE: To change pump voltage, see wiring

diagram on this page or step-by-step instructions

on page 18.