Flint & Walling CPH Convertible Manuel d'utilisation

Page 3

Advertising
background image

4

5

IL0345

3/4 in. Discharge

1-1/4 in.

Suction

1 in.

Pressure

4

Wire Size Chart - Table A

Recommended Copper Wire and Fuse Sizes

HP Rating of Single Phase Motors

Distance

from Motor to

Meter

1/2

3/4

1

0-50’

115V

230V

12 GA

14 GA

12 GA

14 GA

10 GA

14 GA

50-100’

115V

230V

12 GA

14 GA

12 GA

14 GA

10 GA

14 GA

100-150’

115V

230V

12 GA

14 GA

10 GA

14 GA

10 GA

12 GA

150-200’

115V

230V

12 GA

14 GA

10 GA

12 GA

8 GA

12 GA

200-300’

115V

230V

10 GA

14 GA

8 GA

12 GA

6 GA

10 GA

Fuse Size

115V

230V

Amps

20

15

Amps

20

15

Amps

30

15

Ventilation

Ventilation and drainage must be provided to

prevent damage to the motor from heat and

moisture.
Freezing

The pump and all piping must be protected from

freezing. If freezing weather is forecast, drain

pump or remove completely from the system.
Water Supply

The water source must be able to supply enough

water to satisfy the capacity of the pump and

water needs.
Suction Lift

Suction lift is the vertical distance from the

lowest level of the water to the pump intake. See

performance charts on page 2 and 3 to determine

how far your pump can lift water.
Horizontal Distance

The horizontal distance is the horizontal

measurement between the pump suction and the

water source. This distance may affect the ability

of the pump to operate. If it is over 100 feet, call

the manufacturer for assistance at

1-800-742-5044.
Pipe And Fittings

Use galvanized steel or NSF PW Schedule 40

PVC pipe and fittings. This material is designed

for water pressure and will seal against air and

water under pressure. Do Not Use: DWV fittings,

as these are designed for drains without pressure

and will not seal properly. (

Fig. 4)

CAUTION: The entire system must be

air and water tight for efficient operation and to

maintain prime.
Wire Size:

The wire size is determined by the distance from

the power source to the pump motor, and the

horsepower rating of the motor. See the wire chart

on below for proper wire size.

GENERAL PUMP INFORMATION (CONTINUED)

Tools required

PREPARATION

Pipe wrenches (2)

Wire strippers

Needle-nose pliers

Phillips screwdriver

Wire cutters

Adjustable wrench

Pipe tape

Pipe dope

Optional Parts For Assembly

(not included) (Fig 2)

Item Description

1

Ball Valve (plastic)

2

3/4 in. x 1/4 in. bushing (steel)

3

Pressure Gauge

4

Pump stand for tank

5

Well adapter for single pipe packer

installations (straight and right

angle shown)

NOTE: For a successful installation, take time to study your application for the correct pipe size and

appropriate fittings. The illustrations in these instructions will assist you with required and optional

fittings. Sch. 40 PVC plastic pipe and fittings were used in these instructions.

Before beginning installation of product, make sure all parts are present. If any part is missing

or damaged, do not attempt to assemble the product. Contact customer service for replacement

parts.

Estimated Installation Time: 2 hours.

IL1385

lıı

ılı

ııı

lıı

ılı

ııı

lııı

lııı

ılıı

ılıı

ıılııı

lııı

ılıı

ılıı

ıı

200

80

160

140

120

100

80

60

40

20

1

2

3

4

2

5

Parts You May Need For Assembly (Not

Included) (Fig. 1)

Item Description

1

1-1/4 In. union

2

1-1/4 in. adapter

3

1-1/4 in. elbow

4

3/4 in. union

5

1 in. adapter

6

1 in. x 3/4 in. reducer bushing

7

3/4 in. adapter

8

1 in. elbow

9

1-1/4 in. check valve

10

3/4 in. tee (plastic)

11

3/4 in. tee (steel)

12

3/4 in. x 3 in. nipple (steel)

13

3/4 in. plug (steel)

14

Foot valve

Electric cord strain relief

134349 Flow control package

1

IL1382

12

1

4

9

14

11

13

8

10

7

6

5

3

2

Advertising