8

9

Deep Well (Single Pipe System)

Application - Where pumping water level is

greater than 25 feet and inside diameter of well is

2, 2-1/2 or 3 inches. (

Fig 1)

On single pipe deep well installations, clean,

sound well casing must be used to give a tight

seal.

NOTE: This application requires a well adapter

for the top of the well.

NOTE: Pre-soak packer leathers for

approximately two hours before installation.

1. Attach foot valve directly to bottom of ejector

assembly. Ejector must be submerged 10 to

15 feet below pumping water level and the

foot valve must be at least five (5) feet from

bottom of well.

2. Attach foot valve and packer ejector to

suction pipe (presoak packer leathers for

approximately two (2) hours). Push the

assembly down the well. Some force may be

required to push the ejector down the casing.

3. As each section is lowered, check for leaks by

pouring water into the suction pipe.

4. Attach well adapter to suction pipe, lower over

casing top and tighten adapter flange.

5. If no leaks are found, proceed to

WELL TO

PUMP CONNECTION (SUCTION PIPE) using

piping of the same diameter as the suction

pipe (1-1/4”) and pressure pipe (1”) tappings

of the pump. For long offset distances, see

chart on page 9 for the proper pipe size.

6. Unions in suction and discharge piping near

pump and well will aid in servicing. Be sure

to leave enough surrounding room so that

wrenches can be used easily.

IL0209

3/4 or 1 in.

Discharge

Pipe

Suction

Pipe See

Table B

Discharge

to Home

Pipe

Support

Foot Valve

2 in. ID Well

1

INSTALLING PIPING IN WELL (CONTINUED)

WELL TO PUMP CONNECTION (SUCTION PIPE)
Shallow Well Application Only:

CAUTION: Dry-fit entire assembly to ensure proper fit before gluing or taping parts.

CAUTION: Follow all proper gluing procedures as specified by the glue manufacturer. Always

glue in a vertical direction whenever possible to prevent glue from dripping inside pipe or fittings

CAUTION: Use pipe tape and pipe paste compound on all male threads. Tighten with wrench to

a snug fit and add another 1/4 turn to ensure proper seal.

Glue

3

3. The use of a union (optional) will assist with

easy connection and disconnect. (Fig. 3)

IL1346

Glue

2

2. Make the connection to your well. Wrap all

threaded fittings with pipe tape 5 times or

apply a pipe paste (pipe dope) to ensure an air

tight connection. (Fig. 2)

1. Attach ejector to face of pump with two (2)

bolts and gasket provided. Venturi tube on the

ejector inserts into the top tapping of the face

of the pump (Fig. 1).

Priming Port

Venturi

Tube

This Side

Up

Ejector

1

WELL TO PUMP CONNECTION (SUCTION PIPE)

4a. NOTE: For drilled (cased) wells, a foot valve

is required in the well at the end of the pipe

to maintain prime. (

Fig 4a)

IL1187

Water Level

25 ft.

Max

Suction

Lift

3/4 or 1 in.

Discharge Pipe

1-1/4 in.

Suction

Pipe

Discharge

to Home

Pipe

Support

Foot Valve

4a