PUMP PRIMING & STARTUP (CONTINUED)

Deep Well Application Only:

CAUTION: All pumps must be primed

(filling the cavity with water) before they are

first operated. This may take several gallons

of water, as the suction line will be filled in

addition to the pump cavity.

1. Remove the 1/2” priming plug. (

Fig. 1)

1

2

2. Fill pump cavity with water until full and

replace priming plug. (

Fig. 2)

IL1409

3

3. Tighten flow control screw completely by

turning clockwise, then loosen two turns.

Now start the pump. (

Fig. 3)

Pressure

Gauge

4

4. If pump is properly primed, pressure will

quickly build and register on the gauge

mounted directly on the pump body. If

pressure does not build repeat priming

operation. All air must be vented from the

drive and suction pipes as well as the body

before the pump will prime. The pump body

may need to be filled several times in order

to achieve the prime. (

Fig. 4)

PUMP PRIMING & STARTUP (CONTINUED)

5. With pump operating at high pressure, open

two or more faucets and slowly unscrew

the flow control screw until maximum flow

is obtained. This steady pressure will be

minimum operating pressure and should agree

with the pressure shown below. The flow

control screw diverts the proper amount of

water to operate the ejector. (

Fig. 5)

The correct control valve setting will depend on the type of well installation and pressure switch

setting for the particular pump.

NOTE: Flow control is not required for shallow well applications.

IMPORTANT: If the pump fails to prime within five minutes:

Turn power off at the breaker box. Look for leaks or a milky color in the discharged water, which

indicates an air leak. Re-prime if necessary, following steps 1 through 5 above. Reset breaker at the

breaker box. All connections must be water and air tight in order for pump to operate.

IL1409

5

HP

Pressure Setting

1/3

1/2

3/4

1

24 PSI

27 PSI

38 PSI

46 PSI

CARE AND MAINTENANCE

Winterizing

CAUTION: Drain the entire system if

there is danger of freezing. A drain plug is

provided at the bottom of the pump case for

this purpose. (

Fig 1).

IL0345

1

PREVENT

PUMP

DAMAGE!

Remove plug

in freezing

weather

5

5. Thread in priming plug and then open optional

ball valve if installed by turning handle to line

up with the pipe.

(Fig. 5)

6. Turn on breaker to start pump

IMPORTANT: If the pump hums instead of

pumping or turns off repeatedly, shut pump off

immediately.

Check voltage. Make sure your incoming voltage

matches the pump wiring voltage. See wiring

guide in the instructions.