Quick connect multi system installation, Typical plumbing, System diagram – John Wood Concentric Vent - JW98-DVC Manuel d'utilisation

Page 3

Advertising
background image

3

G

Quick Connect
Cord

Gas Supply Piping

Cold Water Supply

Hot Water

Remote Controller

*1

Cord
Connector

Cord
Connector

3.

Quick Connect Multi System Installation

• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick

Connect Cord.

Typical Plumbing

* When connecting two units, disconnect

the remote controller connector from the
other unit.

Note: Connect the remote

controller to only one
of the units.

System Diagram

• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the

cold water supply piping to prevent heat loss and freezing of pipes when exposed to excessively
cold temperatures.

Distance at center:

406 - 812mm (16-32").

Distance on sides

50 - 450mm

(2-18").

Leave enough clearance around the plumbing

to apply insulation. It will be necessary to add

bends to the piping to ensure that this

clearance is available.

Size the piping to allow for the maximum

flow rates of the units.

Union

Hot Water

Shutoff
Valve

Cold Water

Make this distance as short as possible.

* The hot water temperature will

become unstable as the pipe

length increases.

Union

Quick Connect

Cord

Pressure

Relief

Valve

Shutoff
Valve

Union

Gas Valve

Shutoff Valve

The Quick Connect Cord is 2m (6'). long. Install the units 50 - 450mm (2-18") apart from each other
to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).