John Wood Condensing - JWC111-SV Manuel d'utilisation

Page 9

Advertising
background image

9

V

e

n

t

C

le

a

ra

n

c

e

s

W

h

e

n

H

e

a

te

r

is

I

n

s

ta

lle

d

Indoors

• 1.2m (4') below, 1.2m (4') horizontally from,

or 0.3m (1') above any door, operable win-
dow, or gravity air inlet into any building.

0.9m (3') above any forced air inlet within

3m (10').

Maintain the following clearances to any open-

ing in any building:

Illustration

(vent cap)

• 0.3m (1') below, 0.3m (1') horizontally from,

or 0.3m (1') above any door, operable win-
dow, or gravity air inlet into any building.

0.9m (3') above any forced air inlet within

3m (10').

V

ent Clear

ances

When Heater is Installed

Outdoors

With a

V

ent Cap

* All clearance requirements are in accordance with ANSI Z21.10.3 and the National Fuel Gas Code,

ANSI Z223.1 and in Canada, in accordance with CSA-B149.1.

* For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 900mm (36").

To forced air inlets: 1.8m (6'). These clearance requirements hold true for all of the above situations: Indoor,
Outdoor w/vent cap.

0.9m (3')

0.3m (1')

1.2m (4')

1.2m (4')

Clearance Requirements from Vent Terminations to Building Openings

0.3m (1')

0.3m (1')

0.9m (3')

0.3m (1')