Quick connect multi system installation, System diagram, Typical plumbing – John Wood Condensing - JWC111-SV Manuel d'utilisation

Page 3

Advertising
background image

3

G

Quick Connect
Cord

Remote Controller Cord

Gas Supply Piping

Cold Water Supply

Hot Water

Remote Controller

Terminal Block

Cord
Connector

Cord
Connector

3.

Quick Connect Multi System Installation

• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick

Connect Cord.

The Quick Connect Cord is 2m (6'). long. Install the units 50 - 457mm (2-18") apart from each
other to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).

* When connecting two units, use only a

single remote controller.

Note: Connect the remote

controller to only one
of the units.

System Diagram

• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the

cold water supply piping to prevent heat loss and freezing of pipes when exposed to excessively
cold temperatures.

Union

Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.

Quick Connect

Cord

Union

Gas Valve

Union

Shutoff

Valve

Shutoff Valve

Hot Water

Shutoff

Valve

Cold Water

Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.

Size the piping to allow for the maximum
flow rates of the units.

Distance at center:

515 - 922mm (20.3 - 36.3").

Distance on sides

50 - 457mm (2 - 18").

Typical Plumbing