Power+™ Trip Units

Chapter 1. Introduction

3

Cat. No.

Sensor

Rating, A

Plug

Rating, A

TR1C80

80

TR1C100

150

100

TR1C125

125

TR1C150

150

TR4C200

200

TR4C225

225

TR4C250

400

250

TR4C300

300

TR4C400

400

TR8C400

400

TR8C500

500

TR8C600

800

600

TR8C700

700

TR8C800

800

TR16C800

800

TR16C1000

1600

1000

TR16C1200

1200

TR16C1600

1600

TR20C1000

1000

TR20C1200

2000

1200

TR20C1600

1600

TR20C2000

2000

TR32C1200

1200

TR32C1600

3200

1600

TR32C2400

2400

TR32C3200

3200

TR40C1600

1600

TR40C2000

2000

TR40C2500

4000

2500

TR40C3000

3000

TR40C4000

4000

Table 6. Catalog numbers for rating plugs without ground fault. To add

ground-fault protection, append “GF” to the catalog number. To add

defeatable ground-fault protection, append “GFD” to the catalog

number.

Figure 2. Power+ rating plug shown with optional ground-fault

protection function.

CAUTION: Removal of the rating plug while the breaker
is carrying current reduces the breaker’s current-carrying
capacity to approximately 25% of the current sensor
rating. This may result in undesired tripping.

ATTENTION: Si le calibreur est retiré alors que le
disjoncteur est sous tension, le déclencheur se régle
automatiquement à approximativement 25% du calibre
du transformateur de courant. Ceci peut entrainer un
déclenchement indésirable.

Ground-Fault Protection

Ground-fault protection with Power+ Trip Units is pro-
vided as an option in the rating plug. Rating plugs are
available in three configurations:

• No ground-fault protection
• Ground-fault protection
• Defeatable ground-fault protection

Ground-fault protection is activated by installing a rating
plug with the ground-fault option into the Trip Unit. The
pickup and delay settings available with the switches on
the rating plug are described in Chapter 2, Trip Unit Setup.

To order a rating plug with the ground-fault protection
function, find the rating plug in Table 1 with the desired
sensor and plug ratings and append “GF” to the catalog
number. To order a rating plug with the defeatable
ground-fault protection function, append “GFD” to the
catalog number.

WARNING: Rating plugs equipped with ground fault
must be replaced only with other ground-fault-equipped
rating plugs. Failure to do so could result in personal
injury or death, as well as damage to equipment.

AVERTISSEMENT: Les calibreurs munis d’un détecteur
de défaut de mise à la terre ne doivent être remplacés que
par des calibreurs munis d’un détecteur de défaut de
mise à la terre. La non application de cette directive peut
entraîner des blessures ou même provoquer la mort ainsi
qu’endommager l’équipment.