Maintenance – Factory Direct Hardware Danze D500058 Parma Manuel d'utilisation

Page 4

Advertising
background image

Stub out length for tub
spouts (measured from
finished wall surface)

With Flange: 1/2"
Copper pipe stub-out
length from finished
wall surface

Without Flange: 1/2"
Copper pipe stub-out
length from finished wall
surface

With Flange: 1/2"
Brass/IPS pipe stub-out
length from finished wall
surface

Without Flange: 1/2"
Brass/IPS pipe stub-out
length from finished
wall surface

Largo del tubo de
montaje del grifo
(medido desde la
superficie de la pared
terminada)

Con brida: tubo de
montaje de cobre de
1/2" medido desde la
superficie de la pared
terminada

Sin brida: tubo de montaje
de cobre de 1/2" medido
desde la superficie de la
pared terminada

Con brida: tubo de
montaje de bronce
(IPS) de 1/2" medido
desde la superficie de
la pared terminada

Sin brida: tubo de
montaje de bronce (IPS)
de 1/2 medido desde
la superficie de la
pared terminada

Longueur du tuyau qui
dépasse pour les becs
de baignoire (mesurée
à partir de la surface
du mur fini)

Avec bride : Longueur
du tuyau de cuivre de
1/2 po (1,3 cm) qui
dépasse de la surface
du mur fini

Sans bride : Longueur du
tuyau de cuivre de 1/2"
po (1,3 cm) qui dépasse
de la surface du mur fini

Avec bride : Longueur
du tuyau de laiton/IPS
de 1/2 po (1,3 cm)
qui dépasse de la
surface du mur fini

Sans bride : Longueur
du tuyau de laiton/IPS
de 1/2 po (1,3 cm)
qui dépasse de la
surface du mur fini

Sonora, Parma, Opulence,
Brandywood

1-3/8" to 2-1/2"

na

1-5/8" to 1-3/4"

na

Sonora, Parma,
Opulence,Brandywood

1-3/8" a 2-1/2"

n/a

1-5/8" a 1-3/4"

n/a

Sonora, Parma,
Opulence,
Brandywood

1-3/8 à 2-1/2 po
(3,5 à 6,4 cm)

SO

1-5/8 à 1-3/4 po
(4,1 à 4,5 cm)

SO

Bannockburn,
Sheridan, Plymouth,
Melrose

1-1/2" to 2"

1-3/8" to 1-7/8"

1-7/8"

2"

Bannockburn,
Sheridan, Plymouth,
Melrose

1-1/2" a 2"

1-3/8" a 1-7/8"

1-7/8"

2"

Bannockburn,
Sheridan, Plymouth,
Melrose

1-1/2 à 2 po
(3,8 à 5,1 cm)

1-3/8 à 1-7/8 po
(3,5 à 4,8 cm)

1-7/8 po (4,8 cm)

2 po (5,1 cm)

1/2"-14NPT

w/ Fla

nge=1

5/8"

~1 3

/4"

w/ Flange=1

3/8"

~2 1/

2"

Maintenance

Your new faucet is designed for years of trouble-free performance. Keep it looking new by cleaning it periodically

with a soft cloth. Avoid abrasive cleaners, steel wool and harsh chemicals as these will dull the finish and void your warranty.

O.D= ø 5/8"

2.3.2

<2>

<1>

FINISHED WALL

2.3.1

w/o

Flan

ge=

1 3/8"

~1 7/8"

O.D= ø

5/8"

1/2"-14NPT

w/ Flan

ge=

1 7/8"

w/o Fl

ange=2"

w/ F

lange=1

1/2

"~2"

ATTENTION:

Pour s’assurer que le tout fonctionne correctement, la tuyauterie

reliant l’orifice inférieur du robinet à la sortie du bec du bain DOIT consister
soit en un tuyau de cuivre de 1/2 po nominal ou en un tuyau IPS de 1/2 po.

2.3.1 Install shower piping to top port of valve.
Install tub filler piping to bottom port of valve.

Instale la tubería para la ducha en la entrada superior de la válvula.
Instale la tubería para la bañera en la entrada inferior.
Raccorder la tuyauterie de douche à l’orifice supérieur du robinet.
Raccorder la tuyauterie du bec déverseur de baignoire à l’orifice inférieur

du robinet.

2.3.2 Stub-out pipe for spout installation must be at the length illustrated

measured from the finished wall surface.

El tubo de montaje para la instalación del grifo debe sobresalir como se

muestra en la ilustración, midiendo desde la superficie de la pared
terminada.

Le tuyau qui dépasse pour l'installation du bec doit être de la longueur

illustrée, en le mesurant à partir de la surface du mur fini.

Advertising