Connection to PS • Data Compatible Equipment

Note the following when connecting the Disk Recorder to equipment with PS

Data capability.

q Connect the controller and PS

Data equipment at the ends of the PS

Data line.

w Set the termination to ON for the units at both ends of the PS

Data line.

Use the MODE selector on the rear of the WJ-HD500A Disk Recorder to set the termination.

e Use the optional RS-485 cable for connection.

Note:

To be able to use PS

Data mode, the communication functions need to be set up in the PS

Data SETUP menu.

MODE Selector Setting

• Set DIP switch 4 of the MODE selector as follows for data termination.

ON:

If the disk recorder is connected at the end of the PS

Data line.

OFF:

If the Disk Recorder is not connected at the end of the PS

Data line.

Example:

• If the optional WJ-HDB502 Network Board is installed as a controller in the Disk Recorder, the system can be controlled

from a PC through the Disk Recorder.
Set DIP switch 3 of the MODE selector as follows for data termination.

ON:

If the Network Board is connected at the end of the PS

Data line.

OFF:

If the Network Board is not connected at the end of the PS

Data line.

For a system that has no system controller and is controlled through the Disk Recorder, for example, set DIP switch 3 of the
MODE selector to ON position.

Note:

If the system has a system controller, set DIP switch 3 to OFF position.

RS-485 Cable

POWER

ON

OFF

ALARM

Data Multiplex Unit WJ-MP204

ALARM

SUSPEND

1

2

3

4

ESC

SET

RESET

SUSPEND

SET UP

ALARM

UNIT

0

9

8
7

6

5

4

3

2

1

POWER

ON

OFF

ALARM

Data Multiplex Unit WJ-MP204

ALARM

SUSPEND

1

2

3

4

ESC

SET

RESET

SUSPEND

SET UP

ALARM

UNIT

0

9

8
7

6

5

4

3

2

1

RS-485 Cable

(3 : ON, 4 : OFF)

1 2 3 4

O N

MODE Selector

Disk Recorder

Data Multiplex Unit

Termination : OFF

Data Multiplex Unit

Termination : ON

16

16

15

15

14

14

13

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

2

2

3

1

1

SIGNAL GND

10/100BASE-T

SPOT

OUT

IN

EXT STORAGE

COPY

CONTROL

ALARM

VIDEO

MODE

DATA

REMOTE(WV-CU50)

GEN-LOCK OUT

SERIAL

POWER

ON

AC
IN

OFF

IN

OUT

OUT

MULTI SCREEN OUT AUDIO

RS-485 Cable

POWER

ON

OFF

ALARM

Data Multiplex Unit WJ-MP204

ALARM

SUSPEND

1

2

3

4

ESC

SET

RESET

SUSPEND

SET UP

ALARM

UNIT

0

9

8
7

6

5

4

3

2

1

RS-485 Cable

System Controller

Disk Recorder

16

16

15

15

14

14

13

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

2

2

3

1

1

SIGNAL GND

10/100BASE-T

SPOT

OUT

IN

EXT STORAGE

COPY

CONTROL

ALARM

VIDEO

MODE

DATA

REMOTE(WV-CU50)

GEN-LOCK OUT

SERIAL

POWER

ON

AC
IN

OFF

IN

OUT

OUT

MULTI SCREEN OUT AUDIO

(3 : OFF, 4 : OFF)

1 2 3 4

O N

MODE Selector

System Controller

Termination : ON

Data Multiplex Unit

Termination : ON

Advertising