Lamp/Maintenance Indicators

Maintenance Indicators

• The warning lights on the projector indicate problems

inside the projector.

• There are two warning lights: a TEMPERATURE

WARNING indicator which warns that the projector is too
hot, and a LAMP REPLACEMENT indicator which lets
you know when to change the lamp.

• If a problem occurs, either the TEMPERATURE WARNING

indicator or the LAMP REPLACEMENT indicator will
illuminate red. After turning off the power, follow the
procedures given below.

TEMPERATURE WARNING
indicator

Problem

Maintenance Indicator

Condition

Possible Solution

TEMPERATURE
WARNING
indicator

The internal
temperature is
abnormally high.

• Blocked air intake.

• Relocate the projector to an area with proper

ventilation.

POWER indicator

LAMP REPLACEMENT

indicator

• Cooling fan breakdown.
• Internal circuit failure.

• Take the projector to your nearest Sharp

Authorized Projector Dealer or Service
Center for repair.

• Cooling down.

• Wait until the indicator stops flashing and

turns off.

The indicator flashes in
red.

LAMP
REPLACEMENT
indicator

The lamp does not
illuminate.

• Burnt-out lamp.
• Lamp circuit failure.
• The lamp cage cover is

not securely installed.

• Carefully replace the lamp. (See pages 47

and 48.)

• Take the projector to your nearest Sharp

Authorized Projector Dealer or Service
Center for repair.

The lamp requires
replacement.

• Lamp has been used for

over 1,400 hours.

Problem

• Lamp has been used for

over 1,400 hours.

• Lamp has been used for

over 1,500 hours.

Possible Solution

• Purchase a replacement lamp unit (lamp

cage/module) of the current type BQC-
PGM15X//1 from your nearest Sharp
Authorized Projector Dealer or Service
Center.

• Replace the lamp. (See pages 47 and 48.)

If you wish, you may have the lamp
replaced at your nearest Sharp Authorized
Projector Dealer or Service Center.

Condition

The LAMP REPLACEMENT indicator
illuminates red, and “LAMP” will appear in
yellow in the lower-left corner of the picture.

A significant deterioration of the picture and
color quality occurs.

The power will automatically turn off and
the projector will enter standby mode.

“LAMP” will appear in red in the lower-left
corner of the picture, and the power will
turn off.

Lamp

The lamp in this projector operates for approximately 1,500 cumulative hours, depending on the usage environ-
ment. It is recommended that the lamp be replaced after 1,400 cumulative hours of use or when you notice a
significant deterioration of the picture and color quality. The lamp usage time can be checked with the On-screen
Display. (See page 39.)

CAUTION

• Intense light hazard. Do not attempt to look into the aperture and lens while the projector is operating.

• As the usage environment can vary significantly, the projector lamp may not operate for 1,500 hours.
• “1,500 hours” above indicates average life span and should be used for reference only. This is different than the warranty period.
• For safety, the power will not be turned on from the fourth time when turning on the power without changing the lamp after use for 1,500

hours.

• If the TEMPERATURE WARNING indicator illuminates, follow the above possible solutions and then wait until the projector has cooled down

completely before turning the power back on. (At least 5 minutes.)

• If the power is turned off and then turned on again, as during a brief rest, the LAMP REPLACEMENT indicator may be triggered, preventing

the power from going on. Should this occur, take the power cord out of the wall outlet and put it back in again.

Advertising