Service

CHANGING WATER PUMP OIL

IMPORTANT: Change pump break-in oil after first 20

hours of operation and at 250 hour intervals

thereafter.

1. Put unit on level surface.
2. With water flowing through pump, run unit for a few

minutes to warm oil.

3. Stop engine and close water supply.
4. Remove drain plug (A) to drain oil into container. Do not

pollute; dispose of waste oil properly.

NOTE: Drain plug (A) is located on bottom of pump on

AC-2000GH, AC-2400GH, AC-2400GS and

AC-2600GH washers. It is located at front end of

pump on AC-2500GH, AC-2700GH, AC-2700GS,

AC-3000GS, AC-3300GH and AC-3500GH.

5. Add SAE75W-90 Synthetic oil through fill tube

on AC-2000GH, AC-2400GH, AC-2600GH and

AC-2400GS or HY-GARD® through dipstick holes in

other models (B). Fill to sight glass or to notch/ring in

dipstick. Oil capacity is:

AC-2000GH .......................... 4.5 oz. (0.14 qt., 0.13L)

AC-2400GH .......................... 4.5 oz. (0.14 qt., 0.13L)

AC-2400GS .......................... 4.5 oz. (0.14 qt., 0.13L)

AC-2500GH .......................... 40.6 oz. (1.27 qt., 1.20L)

AC-2600GH .......................... 4.5 oz. (0.14 qt., 0.13L)

AC-2700GH .......................... 14 oz. (0.42 qt., 0.40L)

AC-2700GS .......................... 14 oz. (0.42 qt., 0.40L)

AC-3000GS .......................... 14 oz. (0.42 qt., 0.40L)

AC-3300GH .......................... 15 oz. (0.47 qt., 0.44L)

AC-3500GH .......................... 15 oz. (0.47 qt., 0.44L)

PIC102-101599R0