The Front Panel

NetScreen-ISG 2000

5

The LEDs in the dashboard are as follows:

LED

Purpose

Color

Meaning

POWER

Power Supply

green

Power supply is functioning correctly.

off

System is not receiving power.

red

There is a problem with the power.

ALARM

System Alarm

blinking red

• Continuous blinking indicates a self-test

failure during the ScreenOS bootup. May
also occur due to certain algorithm and ACL
failures.

• Blinks once for each software attack.

amber

One of the following failures has occurred:

• Power supply is turned off.

• Hardware failure.

• Error with software module.

off

No alarm condition present.

TEMP

Temperature

green

Temperature is within safety range.

orange

Temperature is outside normal alarm range.
>132

°F or 56°C

red

Temperature is outside severe alarm range.
>150

°F or 66°C

STATUS

System Status

blinking green

The system is active.

amber

The system is booting.

off

The system is off.

HA

High Availability
Status

green

Unit is master.

amber

Unit is a backup.

red

HA has been defined, but unit is not the
backup system.

off

No HA activity defined.

FAN

Fan Status

green

All fans functioning properly.

red

One or more fans failed or fan subsystem is
not receiving power.

MOD1

green

Security module is installed.

off

No card installed.

MOD2

green

Security module is installed.

off

No card installed.

Advertising