2. routine maintenance – Miller Electric Big Blue 400 PX Manuel d'utilisation

Page 39

Advertising
background image

OM-229 979 Page 33

8-2. Routine Maintenance

!

Stop engine before maintaining.

.

See Engine Manual and Maintenance Label
for important start-up, service, and storage

information. Service engine more often if

used in severe conditions.

Recycle engine

fluids.

n = Check

Z = Change

~ = Clean

l = Replace

* To be done by Factory Authorized Service Agent

Reference

Every

8

Hours

Section 5-6,

8-10

n Coolant Level

n Fuel Level

n Oil Level

~ Oil, Fuel Spills

Every

50

Hours

~ Weld Terminals

Every

100

Hours

Section 8-5

~ Battery Terminals

n Air Cleaner Hoses

n Air Cleaner Element

Every

250

Hours

1/2 in.

(13 mm)

Engine

Manual,

Section 8-6,

8-10

l Unreadable Labels

n Fan Belt Tension

Z Oil Z Oil Filter

n~Spark Arrestor

Every

500

Hours

nl Weld Cables

Z FuelFilter

Z Inline Fuel Filter

nl Thermostat

Every

1000

Hours

OR

SLUDGE

FUEL Section 5-6,

8-4, 8-7,

8-10, and

Engine

Manual

nRadiator Fluid Level

~ Inside Unit

nValve Clearance*

~ Drain Sludge

n~ Slip Rings*

nl Brushes*

Every

2000

Hours

~ Injectors*

Advertising