4. remote voltage/amperage control – Miller Electric Big Blue 400 PX Manuel d'utilisation

Page 36

Advertising
background image

OM-229 979 Page 30

6-4. Remote Voltage/Amperage Control

1

Remote 14 Receptacle RC14

Connect optional remote control to RC14 (see

Section 5-9).

.

When a remote control is connected to the
Remote receptacle, the Auto Sense Re-

mote feature automatically switches volt-

age/amperage control to the remote con-

trol. When a device is connected to the Re-

mote receptacle, remote voltage/amper-

age control is always available regardless

of the position of the Process/Contactor

switch.

0774 / Ref.229 747-B / 804 630-A

Adjust Optional Remote

Control to 100%

Set V/A Control

To Desired Maximum

Weld Output Using Weld

Meters

Set TIG or STICK Process

In Example:

Min = 20 A DC

Max = 205 A DC

Max (205 A DC)

Min (20 A DC)

Connect Remote

Control To Remote

Receptacle RC14

1

Adjust Optional Remote

Control to desired

weld output

Weld meters will always

show the combined main

and remote control setting

and machine welds at

nominal output setting of

the meter.
Weld meters show preset

output when not welding.

Set WIRE Process

Connect Remote

Control To Remote

Receptacle RC14

Adjust Optional Remote

Control to desired

weld output

Advertising