SECTION 7 − OPERATING AUXILIARY EQUIPMENT

7-1. 110 Volt Receptacles

Ref. 229 747-A

1

110 V 32 A AC Receptacle RC11

2

110 V 16A AC Receptacle RC12

3

110 V 16 A AC Receptacle RC13

Receptacles supply 60 Hz single-phase

power.
Maximum output from RC11 is 3.5 kVA/kW.

Maximum output from RC12 or RC13 is 1.8

kVA/kW.
Maximum combined output of all recep-

tacles is 7 kVA/kW.
4

Supplementary Protector CB5

5

Supplementary Protector CB6

Supplementary protector CB5 protects re-

ceptacle RC12 from overload. CB6 pro-

tects RC13 from overload. If a supplemen-

tary protector opens, the receptacle does

not work. Place supplementary protector

switch in the On position to reset breaker.
6

Earth Leakage Circuit Breaker

ELCB 1

7

Earth Leakage Circuit Breaker

ELCB2

8

Circuit Breaker Test Button

ELCB1 protects RC12 and RC13 from

Earth leakage fault. ELCB2 protects RC11

from overload and Earth leakage fault. If ei-

ther circuit breaker opens the correspond-

ing receptacle does not work. Place circuit

breaker switch in the On position to reset

breaker.

.

At least once a month, run engine at
weld/power speed and press test but-

tons to verify ELCB1 and ELCB2 are

working properly.

.

If a circuit protector continues to open,
contact Factory Authorized Service

Agent.

.

Generator power decreases as weld

output increases.