OM-611 Page 18

Return To Table Of Contents

Ref. 098 956-G

Turn Off unit and welding power
source and disconnect input power.

Loosen screw on spark gap access
door and open.

1

Tungsten End Of Point

Do not clean or dress tungsten.
Replace point if tungsten end
disappears.

2

Spark Gap

Normal spark gap is 0.008 in (0.203
mm).

If spark gaps are okay, reinstall
door. If adjustment is needed, con-
tinue as follows:

3

Adjustment Screws

Loosen screws. Place gauge of
proper thickness in spark gap.

4

Pressure Point

Apply slight pressure at point until
gauge is held firmly in gap. Tighten
adjustment screws to 12 in/lbs
torque (overtightening will deform
plastic base). Repeat gauge adjust-
ment with other gap.

Close access door.

5/32 in