1

Operator Control Receptacle
RC1 (See Section 3-6)

2

Keyway

3

Plug

4

Threaded Collar

To connect to receptacle, align
keyway, insert plug, and tighten
threaded collar.

3

4

OR

A

J

B

K

I

C

L

N

H

D

M

G

E

F

1

2

The 14-socket Operator Control receptacle RC1 on the front of the high-
frequency unit is used to connect an optional Amperage Control and/or a
remote start switch to the control circuitry of the high-frequency unit. If this
unit is used with the High-Frequency Selector switch in the Remote 14
position, an optional remote start switch must be connected to the Opera-
tor Control receptacle in order to operate the unit (see Section 4-3
).

3-5.

Operator Control Receptacle Information And Connections

3-6.

Operator Control Receptacle Socket Information

A, B

Contact closure to A completes control circuit for High Frequency and Remote Start switch.

C

+10 volts dc output to remote control.

D

Remote control circuit common.

E

0 to +10 volts dc input command signal from remote control.

Socket Information

*The remaining sockets are not used.