Power source plug information and connections, 4. power source plug information and connections – Miller Electric HF-251D-1 Manuel d'utilisation

Page 15

Advertising
background image

OM-611 Page 11

Return To Table Of Contents

The supplied cord with plugs is for use with CC or CC/CV welding power sources
having the proper, matching 14-pin receptacle. Do not use cordset on machines
without the 14-pin receptacle.

NOTE

159 645-A / Ref. S-0004-A / S-0283-A

Y

Turn Off HF Unit and welding
power source, and discon-
nect input power before
making connections. Stop
engine on welding genera-
tors.

1

Six-Pin Power Source Block
Plug PLG2

2

Supplied Six-Pin Receptacle
RC2

3

Strain Relief Clamp

4

Remote 14 Plug PLG4

5

Keyway

To Connect PLG4 to Remote 14 re-
ceptacle on the welding power
source, align keyway, insert plug
and tighten threaded collar.

Connect Remote 14 Plug PLG4 if remote
contactor and/or remote amperage control
from the HF unit are desired.

A

J

B

K

I

C

L

N

H

D

M

G

E

F

5

4

3

2

1

2

1

6

5

4

3

The following pin information is included
in case the supplied cord is not suitable,
and it is necessary to wire a receptacle
to interface with plug PLG2.

Front View

Of PLG2

Pin*

Pin Informaton

Remote

Contactor Control

Remote

Amperage Control

1, 2

*The remaining pin is not used.

3

4
5

Provides contact closure for Output (Contactor) operation.

Amperage control connection − maximum side.
Amperage control connection − wiper contact.
Amperage control connection − minimum side.

3-4.

Power Source Plug Information And Connections

Advertising
Ce manuel est liée aux produits suivants: