High frequency intensity control, Power switch and pilot light, Postflow timer – Miller Electric HF-251D-1 Manuel d'utilisation

Page 20: Shielding gas, 4. high frequency intensity control, 5. power switch and pilot light, 6. postflow timer, 7. shielding gas

Advertising
background image

OM-611 Page 16

Return To Table Of Contents

1

High Frequency Intensity
Control

Use control to change amount of
HF energy used to start and/or
maintain the arc. Set as low as
practical to prevent interfering with
electronic equipment.

1

4-4.

High Frequency Intensity Control

1

Power Switch

Use switch to turn unit On and Off.

2

Pilot Light

1

2

4-5.

Power Switch And Pilot Light

Postflow Timer

A fixed 15 second Postflow Timer
controls the period of time shielding
gas flows after the arc is extin-
guished.

t

2

4-6.

Postflow Timer

1

Shielding Gas Cylinder

2

Valve

3

Hand Control

4

Foot Control

Open valve on cylinder just before
welding.

Control turns weld output and gas
flow on and off.

Close valve on cylinder when fin-
ished welding.

sb5.2* 5/94 − S-0621-C / S-0769 / Ref. 159 059

2

1

4

OR

3

4-7.

Shielding Gas