Introduction, Simjunior simulator, Simjunior features – Laerdal SimJunior Advanced Manuel d'utilisation

Page 8: General clinical features

Advertising
background image

6

Introduction

SimJunior Simulator

SimJunior facilitates interactive training of life-saving skills and responds
to clinical intervention by instructor control and/or pre-programmed
scenarios for effective practice of diagnosis and treatment of a patient.

With spontaneous breathing, airway control, voice, sounds, ECG, and
other clinical features, SimJunior is a fully functional pediatric simulator.
SimJunior allows observation and recognition of most vital signs, which
enables the instructor to assess the student’s skills based on a realistic
clinical situation.

SimJunior Features

– Realistic airway for simulation of difficult airway management, oral,

and nasal intubation

– Observable breathing
– Cardiac features, including defibrillation and cardioversion
– Eyes with interchangeable pupils (normal, dilated, or constricted)
– Convulsions to simulate seizures
– Chest compressions
– Vascular access
– Normal and abnormal heart, breath, and bowel sounds

– Automatic Simulation Control based on pre-programmed and

validated patient scenarios

Simulations can run autonomously using scenarios on the SimPad or
with LLEAP (PC). The development of the patient’s condition is pre-
programed and automatically responds according to the participant
interventions.

Overall Dimensions

Length / Width (Simulator only): 45 in x 9.84 in (120 cm x 42.5 cm)
Weight (Simulator only): 25 lbs (11.36 kg)

SimJunior Clothing

SimJunior comes with custom designed clothing with Velcro openings
for easy removal. Washing instructions are found on the clothing label.

– Shirt

– Shorts

– Boxer Shorts

General Clinical Features

Airway Features

The airway is anatomically correct to the trachea. The airway can be
manipulated by:

– Head tilt/chin lift

– Jaw thrust with articulated jaw

– Cricoid pressure and manipulation

– Suctioning (oral and nasopharyngeal)

The Simulator may be ventilated by normal and emergency methods:

– Bag-mask ventilation

– Orotracheal intubation

– Nasotracheal intubation

Prior to using airway devices, lubricate with Laerdal Airway Lubricant.

The following equipment or methods are suitable to secure the
Simulator’s airway:

– Laryngeal mask airways (size #2.5)

– Endotracheal tube intubation (size ID 4.5 cuffed, 5.5 uncuffed)

Use of a malleable stylet is recommended. Make sure it does not
extend beyond the ET tube.

The following Simulator conditions indicate incorrect tube placement:

– Right main stem intubation – unilateral chest rise

– Stomach distention

– Lack of chest sounds (see Breathing section)

Simulator features may be configured to present various airway
scenarios:

– Tongue edema - normal, medium, maximum levels

– Lungs open or closed

Breathing Features

SimJunior can simulate spontaneous breathing with visible chest rise
and fall and variable breathing rates. The breathing is generated by an
enclosed air compressor in the Simulator’s right thigh.
– Bilateral chest rise and fall with spontaneous breathing

– Unilateral chest rise and fall with right mainstem intubation during

ventilations

– Unilateral and bilateral lung sounds
– Normal and abnormal breath sounds
– Variable respiration rate (0-60 breaths per minute)
– Anterior auscultation sites (4)

The left lung and right lung can be closed independently or together
to create a partial or complete airway obstruction. The SimJunior
Simulator can also be used with assisted ventilations.

Note: Lungs are not intended for use with PEEP-valves.

Advertising