ALARM SETUP

Move the cursor to ALARM SETUP in the WJ-HD500
SETUP menu by pressing the

A

or

T

button, then

press the SET button.

The ALARM SETUP menu shown below appears on the

monitor screen.

G AUUtM SETXJP

AIJUIH

TERMIHAL SETUP

’ i

AUTO RESET

OFF

ALARM OUTPUT

2S

A1.ARH BUZZER

2S

VIDEO LOSS

ON

VIDEO

MOTION DETECTION

OFF

VMD AREA SETUP "I

ALARM MODE MULTI OUTPUT

SPOT

SPOT OUTPUT

SPOT

2. Select an item or item parameter in the menu by press­

ing the

A

or

T

button.

4. Move the cursor to the INPUT editing area by pressing

the ► button, then select the type of contact to meet
the system requirement by pressing the Q or B but­
ton.

N.O: Accepts alarm input from Normally Open con­

tacts.

N.C; Accepts alarm input from Normally Closed con­

tacts.

The factory default setting is N.O.

5. Repeat the above steps 2 to 4 to designate the other

input channels.

6. When satisfied with all of the above steps, press the

SETUP/ESC button to return to the previous ALARM

SETUP menu.

3. To return to the previous WJ-HD500 SETUP menu,

press the SETUP/ESC button.

■ Alarm Port Setting

This item lets you designate the alarm input from the
ALARM port located on the rear of the Disk Recorder.

1. Move the cursor to ALARM TERMINAL SETUP in the

ALARM SETUP menu by pressing the

A

or

T

button,

then press the SET button.
The table shown below appears on the monitor screen.

G-1 ALARM

TERMINAL SETUP

ALH CAM INPUT

ALM CAM INPUT

ICH

1

N.O

9CH

9

N.O

2CH

2

N.O

lOCH

10

N.O

3CH

3

N.O

IICH

11

N.O

4CH

4

N.O

12CH

12

N.O

5CH

5

N.O

13CH

13

N.O

6CH

G

N.O

14 CH

14

N.O

7CH

7

N.O

15CH

15

N.O

8CH

8

N.O

16CH

IG

N.O

2. Move the cursor to the input channel editing area by

pressing the

A

or

f

button.

3, Select a camera number (1 - 16) corresponding to the

input for the CAM editing area by pressing the (±) or 0
button.

■ Alarm Auto Reset Setting

This item lets you select the duration the Disk Recorder

retains the alarm mode before resetting automatically.

1. Move the cursor to the AUTO RESET parameter in the

ALARM SETUP menu by pressing the

A

or ▼ button.

2. Select the desired duration by pressing the 0 or Q

button,

OFF: Disables auto reset.

1S - 30S, 40S, 50S, 1M - 5M: Selects an alarm duration

between 1 second and 5 minutes.

The factory default setting is OFF.

■ Alarm Output Setting

This item lets you select the output duration of the alarm

signal from the ALARM port.

1. Move the cursor to the ALARM OUTPUT parameter in

the ALARM SETUP menu by pressing the

A

or

T

but­

ton.

2. Select the desired duration by pressing the 0 or 0

button.

OFF: Disables alarm output, regardless of an incoming

alarm.

IS - 30S, 40S, SOS, 1M - 5M: Selects an alarm duration

between l second and 5 minutes.