■ Alarm Recording (Manual Recording)

These items let you set the recording mode in Time Lapse

Recording when an alarm is activated during manual
recording.

1. Move the cursor to the ALARM REC MODE parameter

by pressing the

A

or

T

button, then select a recording

time mode by pressing the [+) or Q button.
The parameters are the same as MANUAL REC MODE.

The factory default setting is SF-24H.

2. Move the cursor to the REC RATE parameter by press­

ing the

A

or

T

button, then select a recording rate by

pressing the

E

or □ button.

For details refer to REC RATE in this menu.

3. Move the cursor to the REC QUALITY parameter by

pressing the

A

or ▼ button, then select a recording

image quality by pressing the (+] or Q button.
For details refer to REC QUALITY in this menu.

4. Move the cursor to the DURATION parameter by press­

ing the

A

or ▼ button, then select an alarm recording

duration by pressing the 0 or Q button.

OFF: Disables alarm recording.

10S - 6M: Enables alarm recording for between 10 sec­

onds and 6 minutes.

MANUAL: Enables alarm recording while the alarm sig­

nal is received from the ALARM port.

CONTINUE: Enables alarm recording until the REC

STOP is pressed.

The factory default setting is 10S.

5. Move the cursor to the DYNAMIC REC parameter by

pressing the

A

or ▼ button, then select an alarm

recording pattern by pressing the 0 or Q button.

OFF: Records all input images starting from input 1.

ALM-PRI: Records the alarmed input images preferen­

tially over other video inputs,

ALM'ONLY: Records the particular images that have

activated the alarm.

The factory default setting is OFF,

45