2. Move the cursor to the TIMER REC MODE parameter in

the menu by pressing the

A

or ▼ button.

3. Select the recording time mode to be set by pressing

the E) or Q button.

SF-*HsH or SF-A**H:H: Selects the recording time

mode in enhanced fine quality,

FQ-H:^H or FQ-A*H«HtH: Selects the recording time

mode in fine quality.

NQ-**H or NQ-A*^*H: Selects the recording time

mode in normal quality.

EX-HiHiH or EX-A*^*H: Selects the recording time

mode in extended quality.

SP or SP-A*: Freely selectable

indicates the hours for recording time mode:

2, 12, 18, 24, 48, 72, 96. 120, 180, 240, 360, 480,

720, 960, 1200, 1440, 2160, 2880, 3600, 4320,

6480, 8640

(parameter A* indicates recording with audio)

When the parameter SF/FQ/NQ/EX is selected for

recording time, the recording rate and quality are auto­
matically set according to the selected recording time.

Note: It may not be possible to set the recording time,

depending on the remaining storage capacity of the
hard disk.

The factory default setting is SF-24H.

4. If the parameter SP is selected for recording time, move

the cursor to the REC RATE parameter by pressing the

A

or

T

button, then select a recording rate by pressing

the 0 or (3 button.

1 - 30FPS: Records the selected number of freeze

images every second.

0.5FPS: Records a freeze image every 2 seconds.
0.4FPS: Records a freeze image every 2.5 seconds.
0.3FPS: Records a freeze image every 3.3 seconds.

0.2FPS: Records a freeze image every 5 seconds.
0.1 FPS: Records a freeze image every 10 seconds.

• 30FPS is the active selection when the FIELD/FRAME

parameter in the COMMON REC SETUP menu is set to
FIELD .

• 15FPS is the active selection when the FIELD/FRAME

parameter in the COMMON,REC SETUP menu is set.to

FIELD or FRAME 3DIM OFF.

Move the cursor to the REC QUALITY parameter by
pressing the

A

or

T

button, then select a recording

image quality by pressing the 0 or 0 button.

SUPER FINE: For enhanced sharpness (Compression

Rate 1/6)

FINE: For fine image quality (Compression Rate 1/10)
NORMAL: For normal image quality (Compression Rate

1/16)

EXTENDED: For extended time recording quality

(Compression Rate 1/25)

• Alarm Recording

These items let you set the recording mode in Time Lapse

Recording when an alarm is activated during the recording

with the internal programmed timer.

1. Move the cursor to the ALARM REC MODE parameter

by pressing the

A

or

T

button, then select a recording

time mode by pressing the 0 or 0 button.
The parameters are the same as TIMER REC MODE.

For details refer to TIMER REC MODE in this menu.

2. Move the cursor to the REC RATE parameter by press­

ing the

A

or

T

button, then select a recording rate by

pressing the 0 or 0 button.
For details refer to REC RATE in this menu.

3. Move the cursor to the REC QUALITY parameter by

pressing the

A

or

T

button, then select a recording

image quality by pressing the 0 or 0 button.
For details refer to REC QUALITY in this menu.

4. Move the cursor to the DURATION parameter by press­

ing the

A

or ▼ button, then select the alarm recording

duration by pressing the 0 or 0 button.

10S - 6M: Enables alarm recording for between 10 sec­

onds and 6 minutes.

MANUAL: Enables alarm recording while the alarm sig­

nal is received from the ALARM port.

CONTINUE: Enables alarm recording until the REC

STOP is pressed.

The factory default setting is 10S.

5. Move the cursor to the DYNAMIC REC parameter by

pressing the

A

or

T

button, then select an alarm

recording pattern by pressing the 0 or 0 button.

OFF: Records the images assigned to the group inputs

including the one which has activated the alarm.

ALM-PRI: Records the alarm input images preferential­

ly over other video inputs.

ALM-ONLY: Records the particular images that have

activated the alarm.

The factory default setting is OFF.