Electrical connection – Vintage Cellars 6SDZE Manuel d'utilisation

Page 5

Advertising
background image

• Do not splash or spray water from a hose on the wine

cellar. Doing so may cause an electrical shock, which may

result in severe injury or death.

• This unit should not, under any circumstances, be installed

to an un-grounded power supply.

Electrical Connection

A grounded 115 volt, 15 amp dedicated circuit is required.

This product is factory equipped with a power supply cord that

has a three-pronged, grounded plug. It must be plugged into a

mating grounding type receptacle in accordance with the Na-

tional Electrical Code and applicable local codes and ordinances

(see Figure 5). If the circuit does not have a grounding type re-

ceptacle, it is the responsibility and obligation of the customer to

provide the proper power supply. The third ground prong should

not, under any circumstances, be cut or removed.

Figure 5

Do not use an extension cord with

this appliance.

ELECTRICAL CONNECTION

Figure 4

Toe kick (Front Grille)

Toe kick screw

5

NOTE

Ground fault circuit interrupters (GFCI) are prone to nuisance

tripping which will cause the unit to shut down. GFCI’s are gener-

ally not used on circuits which power equipment that must run

unattended for long periods of time, unless required to meet

local building codes and ordinances.

The unit must be installed according to your local building codes

and ordinances.

Advertising