Never Leave Heater UNatteNded

wHiLe bUrNiNg, coNNected to a

power soUrce or wHiLe

coNNected to a fUeL soUrce.

Ventilation

Lighting Instructions

Storage / Maintenance

- a two-car garage door open 6 inches, or

- a single car garage open 9 inches, or

- two thirty two inch wide windows open 15 inches.

TO START

1. Connect power cord to a properly grounded three (3) prong

120V, 60 Hz, extension cord.

Extension Cord Wire Requirements:

6 to 10 feet (1.8 to 3 meters) long, use 18 AWG conductor.

11 to 100 feet (3.4 to 30.53 meters) long, use 16 AWG

conductor.

101 to 200 feet (30.8 to 61 meters) long, use 14 AWG

conductor.

2. Connect heater to a proper LP cylinder.

3. Turn gas valve clockwise to OFF position.

4. Wait five (5) minutes for any gas to clear. Smell for gas; if you

do not smell gas, go to Step 4.

5. Push in and turn gas control knob counterclockwise to

LOW/IGN position. This will light the burner. If needed, keep

pressing control knob until the burner lights and keep pressing

and turning from OFF to LOW/ IGN on Piezo electric spark

models

6. Keep the valve knob depressed for at least 30 seconds after

lighting the burner. After 30 seconds, release valve knob.

7. If burner does not stay lit, repeat lighting procedure.

8. When burner stays lit, turn gas valve knob counterclockwise to

desired setting

SHUTDOWN INSTRUCTIONS

To shut off heater:

1. Turn gas valve knob clockwise to OFF position.

2. Turn gas supply OFF by turning LP cylinder valve clockwise to

close.

3. Disconnect the power cord.

TEST FIRING THE HEATER

Test fire your construction heater following the lighting instructions

applicable to the gas control system employed.

Leak test all gas connections with 50/50 soap and water solution

prior to start-up. Soap bubbles indicate a gas leak. DO NOT use

a match or flame to test for gas leaks.

NOTE

: Heater surface temperature must be cold before initiating

service, cleaning or storage.

Always provide a fresh air opening in the

heated space of at least three square feet

(2,800 sq. cm.) for each 100,000 BTU/hr of

heater output.

Caution

Model #s: PT-16-TTC (Single Burner),

PT-32-TTC (Double Burner),

PT-47-TTC (Triple Burner)

User’s Manual and

Operating Instructions

Propane

Tank Top Heaters

IMPORTANT:

Read and understand all of the direc-

tions in this manual before assembling, starting or servic-

ing the heater. Improper use of this heater can cause

serious injury. Keep this manual for future reference.

CONSUMER: Retain this manual for future reference.

Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA

Phone: 215-891-8460 Fax: 215-891-8461 Web: www.pinnacleint.com Email: [email protected]

Table of Contents

Safety Information.........................................................2-3

Product Identification........................................................3

Propane Supply................................................................3

Ventilation............................................................3

Assembly..........................................................................3

Connecting Heater to Cylinder..........................................4

Lighting Instructions..........................................................5

Maintenance and Storage.................................................6

Replacement Parts List.....................................................6

Exploded Parts Drawing...................................................7

Warranty...........................................................................8

201000016-12

Carbon Monoxide Hazard This heater produces carbon monoxide, which has no odor. Burning the

heater in an enclosed space can kill you. Never use the heater in enclosed spaces such as a tent, a

camper, any vehicle or recreational vehicle (RV), enclosed shelter, or any other enclosed areas.

Not for use in residential living areas or in non-adequately ventilated enclosed spaces. Never

bring or store a propane cylinder indoors.

WARNING

DANGER

OUTDOOR USE ONLY

S I G

E

N

D

C E

D

R

I E

T I F

CERTIFIED

FAILURE TO COMPLY WITH THE

PRECAUTIONS AND INSTRUCTIONS

PROVIDED WITH THIS HEATER, CAN

RESULT IN DEATH, SERIOUS BODILY

INJURY AND PROPERTY LOSS, OR

DAMAGE FROM THE HAZARDS OF FIRE,

EXPLOSION, BURN. ASPHYXIATION,

CARBON MONOXIDE POISONING AND / OR

ELECTRIC SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND

AND FOLLOW THE INSTRUCTIONS

SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER

INFORMATION SUCH AS AN INSTRUCTION

MANUAL, LABELS, ETCETERA, CONTACT

THE MANUFACTURER.

Always disconnect the heater from the LP cylinder before putting

the heater into storage. If for any reason the heater is to be

stored indoors, the tank MUST be disconnected from the LP

cylinder, and the cylinder stored outdoors in a well-ventilated

area, out of the reach of children, and in accordance with the

Standard for Storage and Handling of Liquefied Gases,

ANSI/NFPA 58 - latest edition and Natural Gas and Propane

Installation Code, CSA 149.1. The plastic valve plug or valve

cover supplied with the cylinder must be re-installed on the valve

to protect the fitting from damage.

Always be sure to follow proper maintenance procedures. This

should include cleaning the inside the heater once a month, and

checking the spark gap at least once a heating season.

Never store an LP cylinder inside of a building,

or near any other gas or oil burning appliances.

NOTE: Installation and repair of this heater should be done
by a qualified service person.