Mas te r s eri es g as x pr es s g rill, Dimensions & specifications, xg24 – Garland XG36 GAS XPRESS GRILL Manuel d'utilisation

Page 4

Advertising
background image

Part # 4517124 Rev. 7 (08/17/11)

Page 4

Garland Commercial Ranges Ltd

1177 Kamato Road,

Mississauga, Ontario

L4W 1X4 CANADA

Phone: 905-624-0260

Fax: 905-624-5669

M

as

te

r S

eri

es

G

as

X

pr

es

s G

rill

Form# XG24 (08/02/10)

25-1/2"

[646mm]

AVERAGE

23"

[584mm]

MAX

44.03°

AVERAGE

[48° MAX]

33-25/32"

[858mm]

24-1/8"

[614mm]

11-1/2"

[292mm]

ÉLÉMENT CHAUFFANT

SUPÉRIEUR

(2 ENDROITS)

TOP VIEW

24"

[610mm]

GRILL

PLATE

DEPTH

40-1/4"

[1022mm]

24"

[610mm]

GRILL PLATE WIDTH

3/4"

NPT

GAS

INLET

28-3/16"

[716mm]

FRONT VIEW

11-1/4"

[286mm]

RIGHT SIDE VIEW

7" [178mm] MIN

11" [279mm] MAX

26-23/32"

[678mm]

FROM PLATEN

ARM PIVOT

50-1/2"

[1282mm]

AVERAGE

4-41/64"

[118mm]

1-23/32"

[44mm]

2-3/4"

[70mm]

25-7/8"

[656mm]

38-25/64"

[975mm]

Model

Total

kW

Load

Loading kW/

Phase

Nominal Amps Per Line

208/220/240V 3ph

208V

220V

240V

1-Ph

3-Phase Delta

1-Ph

3-Phase Delta

1-Ph

3-Phase Delta

X-Y

X-Z

Y-Z

L1-L2

X

Y

Z

L1-L2

X

Y

Z

L1-L2

X

Y

Z

XG24

8.66

2.66

3.33

2.66 41.63 24.90 22.14 24.90 39.36 23.50 20.94 23.50 36.08 21.61 19.19 21.61

XG24-1

L/R

4.33

1.33

1.65

1.33 20.82 12.14 11.07 12.14 19.68 11.75 10.47 11.75 18.04 10.80 9.59 10.80

XG24-F

0.66

0.66

3.17

2.74

2.74

3.00

2.59

2.59

2.75

2.38

2.38

Model

Total

kW

Load

Loading kW Per Phase

Nominal Amps Per Line

380/400/415V

380V

400V

415V

L1/N L1/L2 L1/L3 L2/L3 L1/N

L1

L2

L3

L1/N

L1

L2

L3

L1/N

L1

L2

L3

XG24CE

8.74

0.74

2.66

2.66

2.66

3.36 15.90 12.46 12.46 3.22 13.40 11.55 11.55 3.08 12.10 11.11 11.11

XG24CE-1

L/R

4.56

0.56

1.33

1.33

1.33

2.54

7.33 6.02 6.02 4.30 19.80 17.32 17.32 4.12 18.75 16.70 16.70

XG24CE-F

0.38

0.38

0.00

0.00

0.00

1.72

1.00 0.00 0.00 1.58 0.95 0.00 0.00 0.91 12.10 11.11 11.11

Clearances

Gas Pressure

Total Input

Entry

Installation

Supply (min.)

Operating

Crated

Uncrated

Sides

Rear

NAT

PRO

NAT

PRO

BTU/Hr

kW

47-1/2"

(1207mm)

32"

(813mm)

6"

(152mm)

3"

(76mm)

7.0" WC

11.0" WC

3.5" WC

3.5" WC

66,000

19.4

DIMENSIONS & SPECIFICATIONS, XG24