ERROR LOGIC & TROUBLESHOOTING continued

Platen Down Error

Gas Ignition Error

Occurs when the ignition

feedback signal does not

respond after 4 tries.

Error

not self-

correcting

Press On/

Off key to

cancel.

Audio Alarm

L1: IGNITION ERROR
L2:

COMM Error

Occurs when

communication fails between

the main control and the motor

speed controller.

Error

not self-

correcting

Press On/

Off key to

cancel.

Audio Alarm

L1: COMM ERROR
L2:

Motor Overcurrent Error

Occurs when current to the motor

exceeds 4.8 amps, typically because

platen movement has encountered

mechanical resistance

Error

not self-

correcting

Press Raise

Button to

cancel.

Audio Alarm

L1: MOTOR
L2: OVERCURRENT

Motor Error

Occurs when the platen is in normal

up or down motion between limits,

but fails to generate 5 encoder

counts in any 1-second interval.

Recycle Main

Power Switch

Audio Alarm

L1: MOTOR
L2: ERROR

Occurs at cycle-start when the

platen fails to reach lower limit

position within 40 sec.

Error

not self-

correcting

Press On/

Off key to

cancel.

Audio Alarm

L1: PLATEN DOWN
L2:

Platen Up Error

Occurs at cycle-end when the

platen fails to reach upper limit

position within 40 sec.

Error

not self-

correcting

Press On/

Off key to

cancel.

Audio Alarm

L1: PLATEN UP
L2:

Advertising