Gas Hook-Up Instructions

LP (Propane) Gas

Attach cylinder retaining bracket supplied to the base of the cylinder. Then secure to the surface to which

it sits. Cylinder should be on a level surface.

Cylinder Retaining Bracket

1. Fasten the bracket to the bottom of the propane bottle using

bolt and nut supplied.
2. Tighten the lag screw into the mounting surface leaving

approximately 1/4” of thread above the surface.
3. Slide propane bottle into position so that the bracket slides

under the head of the lag screw.
4. Tighten the lag screw onto the bracket.
5. For fastening to a concrete surface a concrete anchor will

be required. (Not supplied)
Cylinder Connection: Ensure the gas regulator hose

is kink free. Remove the cap or plug from the cylinder

fuel valve. Insert the black QCC1 regulator nipple onto

the QCC1 fuel valve. Hand tighten clockwise. Do not use

tools. Leak test all joints prior to using the appliance.

A leak test must be performed annually and each time

a cylinder is hooked up or if a part of the gas system is

replaced.
If this appliance is to be connected directly to a house

propane gas supply line, follow the instructions for

the natural gas hook-up.

WARNING!

If these instructions are not followed exactly, a fire causing death or serious injury may

occur.

Propane Cylinder Specifications

A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a

cylinder with a damaged valve. The LP-gas supply cylinder must be constructed and marked in accordance

with the U.S. D.O.T. Specifications for LP-Gas Cylinders or the Standard for Cylinders, Spheres and Tubes for

Transportation of Dangerous Good and Commission, CAN/CSA-B339, as applicable.
This appliance has been designed for use with a 20 lb. (9.1 kg) or 30 lb (13.6 kg) size propane cylinder only

(not supplied).
The LP-gas supply cylinder must be provided with a cylinder-connection device compatible with the

connection for the appliance. The propane cylinder must be provided with a shut-off valve terminating in

a propane cylinder valve type QCC1, and a safety relief device having direct communication with the vapor

space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the cylinder

shall include a collar to protect the cylinder valve. The LP-gas cylinder must be provided with a listed

overfill protection device (OPD). Do not store a spare LP-gas cylinder under or near this appliance. Never

fill the cylinder beyond 80 percent full.
Use only the pressure regulator and hose assembly provided with this appliance. Replacement pressure

regulators and hose assemblies must be specified by the manufacturer. The regulator supplies a pressure

of 11 inches. water column to the appliance and has a QCC1 type fitting. Cylinders to be used with this

unit must be supplied with a QCC1 cylinder valve. A QCC1 cylinder has a positive seating connection,

which will not allow gas flow until a positive seal has been achieved. It is also equipped with an excess flow

device. In order to attain full flow to the appliance, the valve must be in the off position when the cylinder

valve is turned on.

WARNING!

A fire will result if the gas supply hose makes contact with the underside of the

appliance.