EN

CYLINDER SIZE

OPENING A AREA OPENING B AREA

20 lb (9.1 kg)

20 in

2

(130 cm

2

)

10 in

2

(65 cm

2

)

30 lb (13.6 kg)

30 in

2

(195 cm

2

)

15 in

2

(100 cm

2

)

The enclosure for the LP-gas cylinder shall isolate the cylinder from the burner compartment to provide:
a. Shielding from radiation;
b. A flame barrier; and
c. Protection from foreign material.
Be certain to mount or set the LP gas cylinder on a flat surface and restrain it using the cylinder retaining

bracket to prevent it from tipping.

OPENING

B

NON LOCKING DOOR

PARTITION TO ISOLATE CYLINDER

FROM PATIO FLAME

34” (864 mm)

RECOMMENDED

2” (51 mm)

MINIMUM

OPENING

A

5” (127 mm)

MAXIMUM

5” (127 mm)

MAXIMUM

1” (25.4 mm)

MAXIMUM