2.1 DIMENSIONS

THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to
conform with local codes. Installation practices vary from region to region and it is important to know the
specifi cs that apply to your area, for example in Massachusetts State:

This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth
of Massachusetts.

The appliance damper must be removed or welded in the open position prior to installation of a appliance
insert or gas log.

The appliance off valve must be a “T” handle gas cock.

• The

fl exible connector must not be longer than 36 inches (914.4mm).

A Carbon Monoxide detector is required in all rooms containing gas fi red appliances.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT,

WITH THE GLASS DOOR OPENED OR REMOVED.

PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.

PROVIDE ADEQUATE VENTILATION.

NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.

OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48” (1219.2mm)

FROM THE FRONT FACE OF THE APPLIANCE.

SURFACES AROUND AND ESPECIALLY ABOVE THE APPLIANCE CAN BECOME HOT. AVOID CONTACT

WHEN THE APPLIANCE IS OPERATING.

FIRE RISK. EXPLOSION HAZARD.

HIGH PRESSURE WILL DAMAGE VALVE. DISCONNECT GAS SUPPLY PIPING BEFORE PRESSURE TESTING GAS

LINE AT TEST PRESSURES ABOVE 1/2 PSIG. CLOSE THE MANUAL SHUT-OFF VALVE BEFORE PRESSURE

TESTING GAS LINE AT TEST PRESSURES EQUAL TO OR LESS THAN 1/2 PSIG (35 mb).

USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE.

USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING

COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.

!

WARNING

This appliance must be recessed into a vented noncombustible wood-burning appliance (prefabricated or masonry)
only. The minimum appliance opening size in which the appliance is to be installed is:

HEIGHT 21

1

/

2

"(546.1mm) WIDTH 29"(736.6mm) DEPTH *13

1

/

2

"(342.9mm)

The minimum allowable chimney fl ue size is 7"(177.8mm) round.
*Add 4"(101.6mm) for optional blower.

The minimum distance, from the bottom of a combustible mantel projecting 3"(76.2mm) maximum from the
wall to the top of the appliance, is 14"(355.6mm) (See MINIMUM MANTEL CLEARANCES section).

NOTE: A NON-COMBUSTIBLE HEARTH MUST PROTRUDE A MINIMUM OF 12"(304.8mm) FROM THE
APPLIANCE.

2.2 MINIMUM CLEARANCE TO COMBUSTIBLES

21"

533mm

20 1/2"

521mm

12"

305mm

17 1/2"

445mm

9 1/2"

241mm

17 1/2"

445mm

29 5/8"

753mm

22 7/8"

581mm

13 1/4"

337mm

2.3 GENERAL