Warning, 2 xir3 operation – Napoleon Fireplaces XIR3 Manuel d'utilisation

Page 18

Advertising
background image

W415-1033 / B / 07.15.13

18

EN

6.2 XIR3

OPERATION

IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT

CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH

THE GLASS DOOR OPENED OR REMOVED.

!

WARNING

ROOM

TEMPERATURE

LOW BATTERY

ALARM

CHILD SAFETY

LOCK OUT

TRANSMISSION

AUX. OUTPUT

FAN

FLAME

TEMPERATURE SET POINT/ LEVEL/ STATUS

SPLIT VALVE

35.18A

6.2.1

GENERAL TRANSMITTER LAYOUT

6.2.2

APPLIANCE OPERATION

A.

Install 4 AA batteries into the receiver battery bay as indicated on the battery cover (+/-). (Only required
as back up to household electricity).

B.

Place the 3 position slider switch of the receiver in the “Remote” position.

C.

Using the end of a paper clip, or other similar object, insert the end of the paper clip into the hole
marked “PRG” on the receiver front cover. The receiver will “beep” three (3) times to indicate that it is
ready to synchronize with the transmitter.

D.

Install the 3 AAA batteries in the transmitter battery bay, located on the base of the transmitter.
With the batteries already installed in the transmitter, push the “ON” button. The receiver will “beep”
four times to indicate the transmitter’s command is accepted and set to the particular code of that
transmitter. The system is now initialized.

35.2A

Advertising